We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Intermatic

Intermatic Spring-Wound Timer White 0-6 hr 20A 125VAC

SKU CH-AAJD-WG4AQ

A spring-wound timer with a 0 to 6 hour range, 20 A at 125 VAC, SPST contacts and a hold feature

  • Spring-wound operation needs no external power
  • 0 to 6 hour timing range suits varied cycles
  • 20 A at 125 VAC handles heavy loads
  • SPST contact with hold feature keeps circuit closed
  • CSA and UL listed for code compliance

Spring-Wound Timer 0 to 6 hr

The Intermatic spring-wound timer provides mechanical time control for single-circuit loads up to 20 A at 125 VAC. It suits installers who need a simple, non-electronic delay without external power.

SPST contact with hold feature

The single-pole single-throw contact opens or closes the circuit at the end of the set period. A built-in hold feature lets the operator keep the load on continuously when required, overriding the timed cycle.

1 hp at 120 V and 2 hp at 240 V

The timer handles motor loads of 1 hp at 120 V and 2 hp at 240 V, with resistive ratings of 20 A at 125 VAC, 10 A at 250 VAC and 10 A at 277 VAC. It is not suited for loads exceeding these current or horsepower limits.

Highlights

  • Spring-wound operation needs no external power
  • 0 to 6 hour timing range suits varied cycles
  • 20 A at 125 VAC handles heavy loads
  • SPST contact with hold feature keeps circuit closed
  • CSA and UL listed for code compliance

Specifications

BrandIntermatic

Questions about this item

Will the internal spring mechanism need replacement after repeated winding?

The spring-wound mechanism is a sealed mechanical assembly designed for the 0 to 6 hour timing range; no user-serviceable spring replacement is expected under normal operation.

What is the maximum continuous current the contacts can carry at 125 VAC before tripping?

The SPST contacts are rated for a maximum of 20 amps at 125 VAC, which is the primary current limit for sustained loads.

Does the timer generate noticeable heat or audible ticking when running all day?

As a purely mechanical spring-wound device it produces no electrical heat and only a faint tick from the escapement during the timed cycle.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.