Intermatic
Intermatic Spring Wound Timer 5 Min FD5MW SPST Contactor
Spring-wound timer provides up to 5 minutes of timing with a 20 A SPST contactor rated for 125 VAC
- Spring-wound timing up to 5 minutes with no external power needed
- SPST contactor rated 20 amps at 125 VAC for single-circuit switching
- 1 hp at 120 V and 2 hp at 240 V motor-handling capacity
- 10 amp rating at 250 VAC and 277 VAC for higher-voltage loads
- CSA and UL listed for code-compliant installations
Intermatic Spring-Wound Timer 5 Min FD5MW
The Intermatic FD5MW is a spring-wound mechanical timer rated for a 0 to 5 minute timing range. It uses a single-pole single-throw contact form and fits a single-gang enclosure with a white faceplate and plastic knob. It is suited for installers who need a simple, non-electronic timing control for lighting or motor loads.
Voltage and Current Limits
The contactor carries 20 A at 125 VAC, 10 A at 250 VAC and 10 A at 277 VAC. Motor loads are rated at 1 hp at 120 V and 2 hp at 240 V. It carries CSA and UL listings. The timer has no hold feature, so the circuit opens automatically when the set time expires.
Timing Capacity and Headroom
The 5-minute maximum setting covers short-cycle duties such as fan run-on, pump priming or brief lighting sequences. It runs out for processes that need longer delays or repeat-cycle operation. The single-gang format and lack of a hold function mean it cannot maintain a closed circuit beyond the wound interval without manual reset.
Highlights
- Spring-wound timing up to 5 minutes with no external power needed
- SPST contactor rated 20 amps at 125 VAC for single-circuit switching
- 1 hp at 120 V and 2 hp at 240 V motor-handling capacity
- 10 amp rating at 250 VAC and 277 VAC for higher-voltage loads
- CSA and UL listed for code-compliant installations
Specifications
| Brand | Intermatic |
|---|
Questions about this item
Which timing range should I choose for a short-cycle application?
This model provides a spring-wound timing range of 0 to 5 minutes, suitable for brief intervals.
What does the 1 hp at 120 V rating mean for motor loads?
It indicates the contactor can switch a single-phase motor load up to 1 hp when supplied with 120 VAC.
How does the SPST contact form limit the control circuit?
The single-pole single-throw contact opens or closes one circuit, providing simple on/off control without alternate paths.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



