We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Schneider Electric

Schneider Electric AP7802B Metered PDU 2U 30A 120V 16x NEMA 5-20R

SKU CH-PHGB-6ARHM MPN AP7802B

A 2U metered rack PDU delivering 120 V through sixteen NEMA 5-20R outlets with a NEMA L5-30P input rated for 30 A maximum and 24 A derated current

  • TypeMetered
  • Rack Size2U
  • CertificationsCSA , FCC Part 15 Class A , ICES-003 , UL 60950 , UL Listed
  • ROHSYes
  • Package IncludesCord retention bracket(s), Installation guide, Rack Mounting
  • Input Voltage120V
  • Metered monitoring tracks real-time load on each circuit
  • 16 NEMA 5-20R outlets power dense rack equipment
  • 30 A input with NEMA L5-30P plug supports high-density deployments
  • 2U height and included brackets enable quick rack mounting
  • UL, cUL, CSA and FCC certifications confirm safety compliance

Metered 2U PDU with 16 NEMA 5-20R outlets

The Schneider Electric AP7802B is a metered power distribution unit that occupies 2U of rack space and delivers 120V output through sixteen NEMA 5-20R receptacles. It accepts a NEMA L5-30P input plug rated for 30A maximum current with a regulatory derated limit of 24A. The unit includes overload protection and operates in environments from -5 to 45 °C.

Cord retention and mounting brackets included

The package supplies cord retention brackets to secure connected cables, rack mounting brackets for 2U installation, an installation guide and a user manual. These accessories enable immediate rack integration and help prevent accidental disconnection of critical equipment. No additional software or licences are bundled with the hardware.

Verify 30A 120V supply and NEMA L5-30P compatibility

Before ordering, confirm that the facility provides a 120V 30A circuit with a NEMA L5-30P receptacle to match the PDU input. Ensure the rack can accommodate a 2U device measuring 3.48 x 17.47 x 4.41 inches and that connected loads do not exceed the 24A derated limit. Check that operating temperature and humidity ranges suit the installation site.

Highlights

  • Metered monitoring tracks real-time load on each circuit
  • 16 NEMA 5-20R outlets power dense rack equipment
  • 30 A input with NEMA L5-30P plug supports high-density deployments
  • 2U height and included brackets enable quick rack mounting
  • UL, cUL, CSA and FCC certifications confirm safety compliance

Specifications

BrandAPC
ModelAP7802B
TypeMetered
Rack Size2U
CertificationsCSA , FCC Part 15 Class A , ICES-003 , UL 60950 , UL Listed , cUL Listed
ROHSYes
Package IncludesCord retention bracket(s), Installation guide, Rack Mounting brackets, User Manual
Input Voltage120V
Input Frequency50/60 Hz
Maximum Input Current30A
Regulatory Derated Input Current24A
Input Connector(s)NEMA L5-30P
Output Voltage120V
Output Connector(s)16 x NEMA 5-20R
Overload ProtectionYes
Operating Environment-5 - 45 ºC
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
Dimensions3.48" x 17.47" x 4.41"
Weight7.40 lbs.
Shipping weight6.35 kg
Package size511 × 371 × 147 mm

Questions about this item

Does the Schneider Electric AP7802B have any user-serviceable parts that will need replacement over time?

The unit has no user-serviceable components listed; maintenance is limited to keeping vents clear and verifying the 24 A derated load stays within limits.

What is the first limit reached when the PDU runs at full load continuously?

The regulatory derated input current of 24 A is the binding limit, even though the plug and breaker are rated for 30 A.

How much heat and noise does the AP7802B produce when powering a full 24 A load all day?

As a passive metered PDU it has no fans; heat output equals the small metering electronics loss, and audible noise is effectively zero.