We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
RefurbUPS
Compatible replacement kit with four 12V7A SLA batteries for the Liebert GXT2 1000 UPS 230V
This replacement battery kit is built for the Liebert GXT2-1000RT230 uninterruptible power supply. It contains four 12V7A sealed lead-acid cells assembled into a single cartridge. The pack is designed to restore runtime when the original batteries reach end of life. Factory-fresh stock ensures immediate deployment.
Technicians maintaining this specific UPS will find a direct fit with included installation instructions. The kit does not support other UPS voltages, form factors, or higher-capacity Liebert units. Buyers needing extended runtime beyond the standard cartridge should look at larger-capacity solutions. It is not a standalone power source.
The total energy storage is fixed by the four 12-volt 7-ampere-hour cells wired for the 230V system. This specification determines whether the kit matches the original runtime requirement. No other voltage or ampere-hour combination will fit the GXT2-1000RT230 chassis. Verify the UPS label before ordering.
| Brand | Liebert GXT2 |
|---|---|
| Series | Liebert GXT2 Batteries |
| Type | Kit/Package |
| Weight | 24 |
Remove the front panel, disconnect the old pack, insert the new batteries in the same orientation, reconnect the wiring harness exactly as shown in the included instructions, then replace the panel; the step most often missed is torquing the terminal bolts to the specified value so connections stay secure under load.
The sealed lead-acid cells require no watering or equalising; schedule a visual inspection once a year to check for case swelling, terminal corrosion or loose connections, and run a self-test from the UPS front panel quarterly to verify capacity.
Runtime is the limiting factor; at maximum load the four 12V7A cells deliver only a few minutes of backup before voltage drops below the inverter cutoff, so the UPS will shut down to protect the batteries.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?