2-way normally closed solenoid valve with 1/4 inch brass body, 9/32 inch orifice, 0.88 Cv flow and 24 V AC coil rated to 18 psi air differential
- TypeOther
- 2-way normally closed design controls fluid flow precisely
- 1/4 in pipe size fits standard plumbing connections
- Brass body with NBR seals resists corrosion and wear
- 88 Cv coefficient delivers reliable flow capacity
- 24V AC coil operates safely in watertight environments
Industrial 2-way normally closed valve
This brass solenoid valve controls air or inert gas flow in a normally closed 2-way configuration. It operates on 24V AC power with a 1/4 inch nominal pipe size. The 9/32 inch orifice and 0.88 Cv rating suit low-pressure pneumatic circuits. It is built for industrial fluid control applications.
Watertight coil without junction box
The coil enclosure is rated watertight and ships without an integrated junction box. This changes wiring practice by requiring a separate, suitably rated connection box at install time. NBR seals handle the media compatibility within the stated pressure range. The design simplifies coil replacement without disturbing pipework.
Handles up to 18 psi differential
The valve manages a maximum operating pressure differential of 18 psi for air and inert gas service. Fuel gas and fuel oil duties are not rated, so those media fall outside the approved envelope. Brass construction and NBR seals give chemical headroom for clean, dry pneumatic lines. Pressure spikes beyond the limit will cause seat leakage or failure to open.
Highlights
- 2-way normally closed design controls fluid flow precisely
- 1/4 in pipe size fits standard plumbing connections
- Brass body with NBR seals resists corrosion and wear
- 88 Cv coefficient delivers reliable flow capacity
- 24V AC coil operates safely in watertight environments
Specifications
| Brand | ASCO |
|---|---|
| Type | Other |
Questions about this item
How often should the NBR seals be inspected or replaced on the 8262H210LT?
Inspect the NBR seals during routine system maintenance; replace them if they show wear, swelling or leakage to keep the valve sealing reliably at 18 psi.
What pressure limit is reached first during continuous operation of the 8262H210LT?
The valve is rated for a maximum operating pressure differential of 18 psi for air or inert gas, so that limit governs sustained use.
How much heat does the 24 V AC coil generate when the valve runs all day?
The coil draws 24 V AC continuously; it will warm to normal operating temperature but remains within the watertight enclosure design limits.