Owens Corning
Owens Corning 200261 Drain Trap
Fiberglass pipe insulation with ASJ facing, R-value 16.1, rated for 0 to 1,000 degrees F and plenum use
- TypeDrain Components
- MaterialHAWA
- ColorTan
- Prevents heat loss with R-16.1 fiberglass insulation
- Operates safely from 0 °F to 1,000 °F
- Meets fire codes with 25 flame spread and 50 smoke developed
- Plenum-rated ASJ jacket approved for air-handling spaces
- Slit design with adhesive flap enables fast installation
Insulation for 3/4-inch copper tube
This fiberglass pipe insulation fits 3/4-inch copper tube with a 1-1/8-inch outside diameter. The 2-inch wall thickness delivers an R-value of 16.1 for thermal control. It is supplied in a 3-foot length with a slit, adhesive and flap for installation. The ASJ facing provides a plenum-rated jacket in tan.
Replaces uninsulated or thinner wrap
The product upgrades bare copper or lower-R-value wrap where heat loss or condensation is a concern. The jump is worth it when the system operates between 0 and 1,000 degrees Fahrenheit and requires a flame spread index of 25 and smoke developed index of 50. It also satisfies plenum-rating requirements in mechanical spaces.
Handles high-temperature lines with headroom
The insulation comfortably handles hot-water and steam lines up to the rated maximum temperature. It runs out where the pipe diameter differs from 3/4-inch copper or where a different wall thickness or R-value is specified. The 3-foot length covers a single straight run; longer runs require additional pieces.
Highlights
- Prevents heat loss with R-16.1 fiberglass insulation
- Operates safely from 0 °F to 1,000 °F
- Meets fire codes with 25 flame spread and 50 smoke developed
- Plenum-rated ASJ jacket approved for air-handling spaces
- Slit design with adhesive flap enables fast installation
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Color | Tan |
| Brand | Owens Corning |
| Model | 200261 |
Questions about this item
What copper tube size does the 200261 insulation fit?
The 200261 insulation is designed for 1 1/8 inch copper tube size and 3/4 inch pipe size.
How is the slit with adhesive and flap installed correctly?
Wrap the 3 ft tube around the pipe, remove the protective liner, press the adhesive flap firmly to seal the longitudinal slit, and ensure the ASJ facing overlaps at seams.
When should the fiberglass insulation be replaced?
Replace the insulation if the ASJ facing tears, the fiberglass becomes wet or compressed, or the adhesive flap no longer seals the slit after exposure to temperatures beyond 0 to 1,000 degrees F.