Other Electricities 1x16 PLC Splitter 1U 19" SC/APC Singlemode 50/50 13.8dB 55dB G.657A1
A 1U 19-inch rack-mount PLC splitter divides one singlemode input into 16 SC/APC outputs with a 50/50 ratio, 13.8 dB insertion loss and 55 dB return loss on G.657A1 fibre
- TypeRack Enclosure
- 16 outputs from one input for efficient distribution
- 1U 19-inch rack mount fits standard cabinets
- SC/APC connectors minimise back-reflection at 55 dB
- G.657A1 singlemode fibre bends without excess loss
- 8 dB insertion loss keeps signal strong across 50/50 split
Rack-Mount 1x16 PLC Splitter
This 1U 19-inch rack-mount module houses a 1x16 PLC splitter with SC/APC connectors for singlemode G.657A1 fibre. It is built for network operators who need to divide one upstream feed into sixteen equal paths inside a standard cabinet.
Insertion Loss 13.8 dB Return Loss 55 dB
The passive splitter introduces 13.8 dB insertion loss and maintains 55 dB return loss across the operating band. No power supply or active cooling is required, so the unit adds zero acoustic noise and zero electrical draw to the rack.
SC/APC Singlemode 50/50 Split Ratio
Sixteen SC/APC ports on the front panel accept standard singlemode patch cords and deliver a 50/50 split ratio for balanced distribution. The 1U height preserves rack space for other equipment while the G.657A1 fibre bend tolerance eases cable routing in dense frames.
Highlights
- 16 outputs from one input for efficient distribution
- 1U 19-inch rack mount fits standard cabinets
- SC/APC connectors minimise back-reflection at 55 dB
- G.657A1 singlemode fibre bends without excess loss
- 8 dB insertion loss keeps signal strong across 50/50 split
Specifications
| Type | Rack Enclosure |
|---|
Questions about this item
How do I install the 1x16 PLC splitter in a 19" rack, and what alignment step is often missed?
Mount the 1U enclosure using the front rack ears, then clean and inspect every SC/APC ferrule before mating; the angled polish must be fully seated to avoid high return loss.
What maintenance will the SC/APC connectors and G.657A1 fiber need over time?
Periodic inspection with a fiber scope and one-click cleaning of the SC/APC end-faces; the bend-insensitive G.657A1 fiber requires no special handling beyond standard bend-radius care.
At what insertion loss does the 50/50 split ratio become the limiting factor during sustained operation?
Each output port presents 13.8 dB insertion loss, so the link budget is consumed by the splitter itself before any other component becomes the bottleneck.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lenovo 4X60N04886 Nvidia Quadro P5000 16GB GDDR5X ai accelerator card
- GDDR5
NVIDIA H200 NVL AI Accelerator Card 141GB HBM3e PCIe 5.0 x16 900-21010-0040-000
- PCI Express 5.0 x16
- NVIDIA