Value Brand Embedding O Rings Blue 1.61 In PK500 21RK84
- Assortments & Kits
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Oakton Instruments
Benchtop pH meter covering 0.00–14.00 with automatic temperature compensation up to 100 °C, supplied with a double-junction refillable glass electrode, ATC probe and stand
The Oakton pH 700 is a benchtop instrument designed for laboratory pH measurement across the full 0.00 to 14.00 range. It ships as a complete kit that includes a double-junction refillable glass electrode, an automatic temperature compensation probe and a dedicated probe stand for stable positioning during use.
The meter operates without active cooling, so it produces no fan noise and draws minimal power from its supply during routine measurements. Automatic temperature compensation adjusts readings across the 0 to 100 degrees Celsius displayed range without adding measurable heat or acoustic output to the bench environment.
The double-junction refillable glass electrode extends service life by allowing electrolyte replacement when reference junction performance declines. The ATC probe enables temperature-corrected results without manual calculation, while the supplied stand holds both probes securely to prevent tip damage and ensure consistent immersion depth during testing.
| Brand | OAKTON |
|---|---|
| Type | Environmental & Mechanical |
Connect the electrode BNC and ATC phono plugs to the front panel, seat the probe in the stand, remove the protective cap, and fill the reference chamber with fresh KCl solution before first use.
Refill the reference chamber with KCl solution regularly, rinse the glass bulb with distilled water after each use, and replace the electrode when calibration slope falls below acceptable limits.
The electrode response slows as the reference junction clogs, and the meter reads only up to 100 Degrees C, so temperature compensation stops above that point.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?