Value Brand
Value Brand 12G372 Analog Panel Meter AC Current 0-10 A 2.5 in
Measures AC current from 0 to 10 A with ±1.5 % full-scale accuracy in a 2.5 in panel-mount case
- TypeElectronic
- Measures AC current up to 10 A for panel monitoring
- ±1.5 % full-scale accuracy ensures reliable readings
- 5 inch case fits standard panel cutouts
- Glass-filled polycarbonate case resists impact and heat
- Moving-iron movement operates without external power
Purpose-built panel meter
The Value Brand 12G372 is an analog panel meter designed to measure alternating current from zero to ten amperes. It uses a moving-iron movement housed in a 2.5 inch Rish Vista case made from ten percent glass-filled polycarbonate with a polycarbonate window. Accuracy is rated at plus or minus 1.5 percent of full scale and the unit carries UL listing. A mounting template and screws are included for panel installation.
Suited to fixed AC monitoring
This meter suits technicians and integrators who need a permanent, panel-mounted indication of AC current up to ten amperes. It is not intended for portable troubleshooting, data logging or any application that requires digital read-out, DC measurement or a range beyond the stated ten ampere limit.
Verify panel cut-out and voltage rating
Before ordering, confirm that your panel cut-out matches the 2.5 inch case dimensions and that the circuit voltage is compatible with the meter's insulation rating. Also ensure the operating environment stays within the accuracy specification of plus or minus 1.5 percent full scale for reliable readings.
Highlights
- Measures AC current up to 10 A for panel monitoring
- ±1.5 % full-scale accuracy ensures reliable readings
- 5 inch case fits standard panel cutouts
- Glass-filled polycarbonate case resists impact and heat
- Moving-iron movement operates without external power
Specifications
| Brand | VALUE BRAND |
|---|---|
| Type | Electronic |
Questions about this item
Does the panel meter need an external power supply to operate?
No, the moving-iron movement is self-powered by the measured current so no auxiliary supply is required.
Will the 2.5 in case fit the same cut-out as my existing Rish Vista meter?
Yes, the case style is Rish Vista and the kit includes a mounting template and screws for direct replacement.
How can I verify the meter reads within its 1.5 percent full-scale accuracy after installation?
Apply a known AC current up to 10 A and confirm the pointer deflection stays within 1.5 percent of the 10 A full-scale mark.