We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Nippon Labs

Nippon Labs 80C5CMXE-432BK network ethernet cable Cat5E 1000 ft Black 24 AWG shielded

SKU CH-C124-ZSGMN MPN 80C5CMXE-432BK

Shielded Cat5E bulk cable for direct burial outdoor runs, 24 AWG solid copper with foil shield and drain wire, 1000 ft pull box

  • TypeNetwork Ethernet Cables
  • Cat5E
  • Length1000 ft.
  • ColorBlack
  • ShieldedYes
  • Wire Gauge24 AWG
  • Direct-burial CMX jacket survives outdoor installation
  • F/UTP foil shield blocks interference on long runs
  • Solid 24 AWG copper conductors keep signal loss low
  • 350 MHz bandwidth supports Gigabit Ethernet speeds
  • 1000 ft pull box with metre markings speeds deployment

Outdoor Direct-Burial Cable

This 1000 ft Cat5E bulk cable is built for outdoor and direct-burial installations. The black PE jacket carries a CMX rating for outside plant use. Solid bare copper conductors and an aluminium foil shield (F/UTP) support gigabit ethernet and fast ethernet runs. Installers who need indoor-only patch cables or pre-terminated assemblies should choose a different product type.

350 MHz Shielded Performance

The F/UTP construction with a drain wire reduces alien crosstalk and electromagnetic interference in typical outdoor deployments. Attenuation and near-end crosstalk stay within the limits set by TIA 568C.2 and ISO/IEC 11801 for 350 MHz bandwidth. Sequential length markings on the jacket simplify pulling and measuring. The solid 24 AWG conductors are not suited for repeated flexing or tight patch-panel bends.

Sustained Outdoor Installation

During long pulls the pull-box packaging pays out smoothly without kinking the solid copper pairs. The PE jacket resists moisture and UV exposure over multi-year direct-burial service. Shield continuity depends on proper termination of the drain wire at both ends. Buyers who require plenum-rated cable for indoor vertical runs must select a CMP-listed alternative.

Highlights

  • Direct-burial CMX jacket survives outdoor installation
  • F/UTP foil shield blocks interference on long runs
  • Solid 24 AWG copper conductors keep signal loss low
  • 350 MHz bandwidth supports Gigabit Ethernet speeds
  • 1000 ft pull box with metre markings speeds deployment

Specifications

BrandNippon Labs
Model80C5CMXE-432BK
TypeNetwork Ethernet Cables
Cat5E
Length1000 ft.
ColorBlack
ShieldedYes
Wire Gauge24 AWG
FeaturesHigh-Performance Data Communications Cable
CAT5E Outdoor Direct Burial, Outside Plant
Suitable for 350MHz High-Speed Data Applications, Gigabit Ethernet, Fast Ethernet and 155Mbps TP-PMD/CDDI
Designed for Outdoor Installations (CMX)
Aluminum Foil Shielded w/ Unshielded Twisted Pairs (F/UTP)
4-Pair Easily Identified Color Striped Pairs
24 AWG Solid Bare Copper Conductors
Excellent Attenuation and Crosstalk Characteristics
Exceeds TIA 568C.2, ISO/IEC 11801, And YD/T1019 Specifications
RoHS Compliant
Sequential Length Markings On Jacket
Supplied On A 1000' Pull Box
Shipping weight12.70 kg
Package size381 × 381 × 254 mm

Questions about this item

How do I install this 24 AWG solid copper F/UTP cable for direct burial and what step do people get wrong?

Lay the cable in a trench at the proper depth for your local code, keeping the black PE jacket intact; the step often missed is bonding the drain wire and foil shield at both ends so the shield actually carries noise to ground.

What maintenance or replacement will this outdoor Cat5E cable need later?

The solid 24 AWG conductors and PE jacket are built for permanent burial; no routine maintenance is required, but if the jacket is cut or crushed during later digging, the damaged section must be replaced because solid wire does not tolerate re-termination well.

What limit shows up first on a 1000 ft run under sustained Gigabit traffic?

At 1000 ft the cable exceeds the 100 m channel limit, so attenuation and return loss will degrade 350 MHz performance before the 155 Mbps or 1 Gbps electronics do.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.