Nippon Labs
Nippon Labs 30POW-10W1-C1520-01 14 AWG C15 to C20 1 ft computer power cord
Connects high-temperature network hardware to a PDU or UPS with a C20 inlet using a 1 ft 14 AWG SJT cord with C15 to C20 connectors
- TypePower Cord
- ColorBlack
- Length1 Foot
- Connector Number2
- Connector DetailIEC-60320-C15 to IEC-60320-C20
- SpecificationsConnector A: IEC-60320-C15 Connector B: IEC-60320-C20 Conduc
- Connects high-temperature equipment to C20 PDU or UPS in data centres
- C15 connector fits both C16 and C14 inlets for flexible compatibility
- Heavy-duty 14 AWG SJT conductors rated 15A at 300V for reliable power delivery
- Fully moulded construction resists wear in demanding rack environments
- UL and cUL listed with RoHS and REACH compliant materials
Power cord for high-temperature data-centre gear
This one-foot cable connects equipment that uses a C15 inlet to a PDU or UPS fitted with a C20 outlet. The 14 AWG conductors are rated at 15 amps and 300 volts for reliable power delivery in demanding environments. The C15 plug also fits C16 and C14 inlets, giving flexibility when matching existing rack hardware. It is built for network devices and other high-temperature equipment in data-centre installations.
Fully moulded UL SJT construction
The cord uses UL-listed SJT 14 AWG three-conductor wire with fully moulded connectors for mechanical durability. Both UL and cUL listings confirm compliance with North American safety standards. Materials meet RoHS and REACH directives, so the cable suits regulated deployments. The black jacket keeps cable management tidy in dense rack rows.
Replaces lighter or shorter leads in C20-fed racks
The heavy-duty 14 AWG gauge upgrades from thinner cords that cannot sustain 15 A continuous loads. The one-foot length suits adjacent PDU-to-device runs but will not span wider cabinet gaps. Buyers who need longer reach or a different inlet type should select another cable. The jump is worth it when the existing lead is undersized for the connected load.
Highlights
- Connects high-temperature equipment to C20 PDU or UPS in data centres
- C15 connector fits both C16 and C14 inlets for flexible compatibility
- Heavy-duty 14 AWG SJT conductors rated 15A at 300V for reliable power delivery
- Fully moulded construction resists wear in demanding rack environments
- UL and cUL listed with RoHS and REACH compliant materials
Specifications
| Brand | Nippon Labs |
|---|---|
| Model | 30POW-10W1-C1520-01 |
| Type | Power Cord |
| Color | Black |
| Length | 1 Foot |
| Connector Number | 2 |
| Connector Detail | IEC-60320-C15 to IEC-60320-C20 |
| Specifications | Connector A: IEC-60320-C15 Connector B: IEC-60320-C20 Conductor: UL SJT 14 AWG. x 3C |
| Wire Gauge | 14 AWG |
| Conductor | UL SJT 14 AWG. x 3C |
| Features | Connect network hardware or other high-temperature equipment to a PDU or UPS with C20 type input in a data center. IEC320 C15 connector can fit into both C16 and C14 inlets. This heavy duty 14 AWG power cord is fully molded for durability. UL and cUL listed. All relevant materials are complied with RoHS and REACH directive. |
| Shipping weight | 0.09 kg |
| Package size | 254 × 127 × 38 mm |
Questions about this item
What current and voltage does the IEC-60320-C15 to C20 cord support?
The 14 AWG SJT cable is rated for 15 A at 300 V, matching the C20 inlet specification.
Will the C15 plug fit both C16 and C14 inlets on my equipment?
Yes, the IEC-60320-C15 connector is keyed to mate with either a C16 or a C14 inlet.
How do I install the cord without straining the moulded ends?
Route the 1 ft length so the moulded C15 and C20 bodies sit straight in their inlets; avoid sharp bends right at the connectors.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



