Nippon Labs
Nippon Labs 30POW-10W1-C1419-06 computer power cord C14 to C19 14 AWG 6 ft
A 14 AWG cord linking a C14 plug to a C19 receptacle for server or PDU power distribution
- TypePower
- ColorBlack
- Length6 ft.
- Connector Number2
- Connector DetailIEC-60320-C14 to IEC-60320-C19
- SpecificationsConnector A: IEC-60320-C14 Connector B: IEC-60320-C19 Conduc
- Connects C19 equipment to C14 PDU or UPS outlets in data centres
- Extends existing power runs by six feet for flexible rack layouts
- Heavy-duty 14 AWG conductors rated 15 A at 250 V handle demanding server loads
- Fully moulded strain relief protects connections from repeated insertion cycles
- UL and cUL listed with RoHS and REACH compliant materials
Data-centre power cord
This 6 ft cable connects a C19 receptacle on a server or similar device to a C14 inlet on a PDU or UPS. It is built with 14 AWG conductors rated for 15 A at 250 V. The fully moulded construction meets UL and cUL listings and complies with RoHS and REACH directives.
Thermals noise and power draw
The cord carries up to 15 A at 250 V through its 14 AWG SJT conductors. Passive operation adds no fan noise or active cooling requirement. Voltage drop over the 6 ft length stays within normal limits for the rated current.
Bundled accessories and software
No accessories or software are included with the cable. The fully moulded strain relief is integrated into each connector for durability. Compliance markings are printed on the jacket for quick verification during audits.
Highlights
- Connects C19 equipment to C14 PDU or UPS outlets in data centres
- Extends existing power runs by six feet for flexible rack layouts
- Heavy-duty 14 AWG conductors rated 15 A at 250 V handle demanding server loads
- Fully moulded strain relief protects connections from repeated insertion cycles
- UL and cUL listed with RoHS and REACH compliant materials
Specifications
| Brand | Nippon Labs |
|---|---|
| Model | 30POW-10W1-C1419-06 |
| Type | Power |
| Color | Black |
| Length | 6 ft. |
| Connector Number | 2 |
| Connector Detail | IEC-60320-C14 to IEC-60320-C19 |
| Specifications | Connector A: IEC-60320-C14 Connector B: IEC-60320-C19 Conductor: UL SJT 14 AWG. x 3C |
| Wire Gauge | 14 AWG |
| Conductor | UL SJT 14 AWG. x 3C |
| Features | Connect C19 receptacle to computer, server or other devices and plug C14 connector into a PDU or UPS in a data center. Extend the length of an existing power cord for more flexibility. This heavy duty 14 AWG power cord is fully molded for durability. UL and cUL listed. All relevant materials are complied with RoHS and REACH directive. |
| Shipping weight | 0.36 kg |
| Package size | 191 × 165 × 25 mm |
Questions about this item
How do I connect the C14 and C19 ends to a PDU and server?
Plug the C14 connector into the PDU or UPS outlet, then insert the C19 connector into the server or device power inlet. Ensure both connectors are fully seated; the moulded strain relief prevents accidental disconnection.
What maintenance or replacement will this cord need over time?
Inspect the SJT jacket and moulded ends periodically for cuts, abrasion or heat discoloration. Replace the cord if the 14 AWG conductors become exposed or the connectors no longer latch securely.
What is the first limit reached during sustained 15 A load?
The 14 AWG conductors are rated for 15 A at 250 V; continuous operation at that current will cause the cable to reach its maximum safe temperature before any other limit is encountered.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



