We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Nippon Labs

Nippon Labs 30POW-10W1-C1419-03 3 ft 14 AWG C14 to C19 computer power cord

SKU CH-PAWD-7QX83 MPN 30POW-10W1-C1419-03

A 3 ft heavy-duty 14 AWG cord connects a C19 receptacle on a server to a C14 plug on a PDU or UPS

  • TypePower
  • ColorBlack
  • Length3 ft.
  • Connector Number2
  • Connector DetailIEC-60320-C14 to IEC-60320-C19
  • SpecificationsConnector A: IEC-60320-C14 Connector B: IEC-60320-C19 Conduc
  • Heavy-duty 14 AWG conductors handle 15 A at 250 V
  • C14 to C19 connectors link servers to PDU or UPS units
  • Three-foot length adds reach without excess cable clutter
  • UL and cUL listed for verified electrical safety
  • Fully moulded strain relief protects connections in rack environments

Power connection for C19 equipment

This 3 ft cord carries a C14 plug on one end and a C19 connector on the other, rated at 15 A and 250 V. The 14 AWG UL SJT conductors are fully moulded for durability and the assembly is UL and cUL listed with RoHS and REACH compliance. It is built for data-centre racks where a C19 inlet must reach a C14 outlet on a PDU or UPS.

Suits rack-mount servers and high-draw devices

Administrators wiring equipment with C19 power inlets will find the length and gauge appropriate for standard rack spacing. Installations that require a longer reach, a different connector pairing or a lower current rating should look at other cable configurations.

14 AWG conductor gauge

The 14 AWG UL SJT three-core construction determines the safe current capacity for the connected hardware. Match this gauge to the power-supply requirements of the target device before installation.

Highlights

  • Heavy-duty 14 AWG conductors handle 15 A at 250 V
  • C14 to C19 connectors link servers to PDU or UPS units
  • Three-foot length adds reach without excess cable clutter
  • UL and cUL listed for verified electrical safety
  • Fully moulded strain relief protects connections in rack environments

Specifications

BrandNippon Labs
Model30POW-10W1-C1419-03
TypePower
ColorBlack
Length3 ft.
Connector Number2
Connector DetailIEC-60320-C14 to IEC-60320-C19
SpecificationsConnector A: IEC-60320-C14
Connector B: IEC-60320-C19
Conductor: UL SJT 14 AWG. x 3C
Wire Gauge14 AWG
ConductorUL SJT 14 AWG. x 3C
FeaturesConnect C19 receptacle to computer, server or other devices and plug C14 connector into a PDU or UPS in a data center.
Extend the length of an existing power cord for more flexibility.
This heavy duty 14 AWG power cord is fully molded for durability.
UL and cUL listed.
All relevant materials are complied with RoHS and REACH directive.
Shipping weight0.16 kg
Package size127 × 51 × 51 mm

Questions about this item

What clearance does the 3 ft C14 to C19 cord need behind a rack PDU?

The cord is 3 ft long with fully moulded IEC-60320-C14 and IEC-60320-C19 ends; allow space for the connector bodies and the 14 AWG SJT cable bend radius behind the PDU.

Which end connects to the server and which to the PDU during installation?

Plug the C14 connector into the PDU or UPS outlet and the C19 connector into the server or device receptacle; reversing them will not deliver power.

When should the 14 AWG SJT cable be replaced in a data-centre environment?

Replace the cord if the jacket shows cuts, the moulded connectors crack, or the pins become discoloured from heat; the UL and cUL listing covers the original 14 AWG construction.