Nippon Labs
Nippon Labs 30POW-10W1-C1419-03 3 ft 14 AWG C14 to C19 computer power cord
A 3 ft heavy-duty 14 AWG cord connects a C19 receptacle on a server to a C14 plug on a PDU or UPS
- TypePower
- ColorBlack
- Length3 ft.
- Connector Number2
- Connector DetailIEC-60320-C14 to IEC-60320-C19
- SpecificationsConnector A: IEC-60320-C14 Connector B: IEC-60320-C19 Conduc
- Heavy-duty 14 AWG conductors handle 15 A at 250 V
- C14 to C19 connectors link servers to PDU or UPS units
- Three-foot length adds reach without excess cable clutter
- UL and cUL listed for verified electrical safety
- Fully moulded strain relief protects connections in rack environments
Power connection for C19 equipment
This 3 ft cord carries a C14 plug on one end and a C19 connector on the other, rated at 15 A and 250 V. The 14 AWG UL SJT conductors are fully moulded for durability and the assembly is UL and cUL listed with RoHS and REACH compliance. It is built for data-centre racks where a C19 inlet must reach a C14 outlet on a PDU or UPS.
Suits rack-mount servers and high-draw devices
Administrators wiring equipment with C19 power inlets will find the length and gauge appropriate for standard rack spacing. Installations that require a longer reach, a different connector pairing or a lower current rating should look at other cable configurations.
14 AWG conductor gauge
The 14 AWG UL SJT three-core construction determines the safe current capacity for the connected hardware. Match this gauge to the power-supply requirements of the target device before installation.
Highlights
- Heavy-duty 14 AWG conductors handle 15 A at 250 V
- C14 to C19 connectors link servers to PDU or UPS units
- Three-foot length adds reach without excess cable clutter
- UL and cUL listed for verified electrical safety
- Fully moulded strain relief protects connections in rack environments
Specifications
| Brand | Nippon Labs |
|---|---|
| Model | 30POW-10W1-C1419-03 |
| Type | Power |
| Color | Black |
| Length | 3 ft. |
| Connector Number | 2 |
| Connector Detail | IEC-60320-C14 to IEC-60320-C19 |
| Specifications | Connector A: IEC-60320-C14 Connector B: IEC-60320-C19 Conductor: UL SJT 14 AWG. x 3C |
| Wire Gauge | 14 AWG |
| Conductor | UL SJT 14 AWG. x 3C |
| Features | Connect C19 receptacle to computer, server or other devices and plug C14 connector into a PDU or UPS in a data center. Extend the length of an existing power cord for more flexibility. This heavy duty 14 AWG power cord is fully molded for durability. UL and cUL listed. All relevant materials are complied with RoHS and REACH directive. |
| Shipping weight | 0.16 kg |
| Package size | 127 × 51 × 51 mm |
Questions about this item
What clearance does the 3 ft C14 to C19 cord need behind a rack PDU?
The cord is 3 ft long with fully moulded IEC-60320-C14 and IEC-60320-C19 ends; allow space for the connector bodies and the 14 AWG SJT cable bend radius behind the PDU.
Which end connects to the server and which to the PDU during installation?
Plug the C14 connector into the PDU or UPS outlet and the C19 connector into the server or device receptacle; reversing them will not deliver power.
When should the 14 AWG SJT cable be replaced in a data-centre environment?
Replace the cord if the jacket shows cuts, the moulded connectors crack, or the pins become discoloured from heat; the UL and cUL listing covers the original 14 AWG construction.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



