We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Nippon Labs

Nippon Labs 30POW-10W1-1920-06-R computer power cord 12 AWG C20 to C19 6 ft red

SKU CH-M5CR-B09K7 MPN 30POW-10W1-1920-06-R

A 6 ft red 12 AWG cord links a C19 device to a C20 PDU or UPS at 20A 250V

  • TypePower
  • ColorRed
  • Length6 ft.
  • Connector Number2
  • Connector DetailIEC-60320-C20 to IEC-60320-C19
  • SpecificationsConnector A: IEC-60320-C20 Connector B: IEC-60320-C19 Conduc
  • Heavy-duty 12 AWG conductors support 20 A at 250 V
  • Red jacket enables quick identification in dense racks
  • Fully moulded C20-to-C19 ends withstand repeated insertion cycles
  • Six-foot length extends reach between equipment and PDU or UPS
  • UL and cUL listed with RoHS and REACH compliant materials

Data-centre power link

This Nippon Labs cord carries a C20 plug on one end and a C19 connector on the other, rated for 20A at 250V. The 12 AWG conductors are built to UL SJT standards and are fully moulded for durability. Red jacketing helps technicians trace the cable quickly in dense rack rows. It suits servers, storage arrays or PDU connections where a secure IEC-60320 link is required.

Thermals noise and power

A passive cable generates no heat of its own and produces no audible noise during operation. The 12 AWG copper cross-section keeps resistive losses low at the rated 20A load, so the cord stays cool to the touch in normal rack temperatures. No fan, pump or active cooling is involved, and there is no power draw beyond the current flowing to the attached equipment.

Sustained load behaviour

Under continuous 20A duty the cord maintains its voltage rating without derating, thanks to the heavy-gauge UL SJT construction. The moulded strain reliefs resist fatigue from rack vibration or cable-management tension over long deployments. RoHS and REACH compliant materials ensure the insulation does not degrade in warm aisle environments. The six-foot length adds reach without introducing excess voltage drop for typical data-centre runs.

Highlights

  • Heavy-duty 12 AWG conductors support 20 A at 250 V
  • Red jacket enables quick identification in dense racks
  • Fully moulded C20-to-C19 ends withstand repeated insertion cycles
  • Six-foot length extends reach between equipment and PDU or UPS
  • UL and cUL listed with RoHS and REACH compliant materials

Specifications

BrandNippon Labs
Model30POW-10W1-1920-06-RD
TypePower
ColorRed
Length6 ft.
Connector Number2
Connector DetailIEC-60320-C20 to IEC-60320-C19
SpecificationsConnector A: IEC-60320-C20
Connector B: IEC-60320-C19
Conductor: UL SJT 12 AWG. x 3C
Amp/Voltage Rating: 20A/250V
Wire Gauge12 AWG
ConductorUL SJT 12 AWG. x 3C
FeaturesConnect C19 receptacle to computer, server or other devices and plug C20 connector into a PDU or UPS in a data center.
Extend the length of an existing power cord for more flexibility.
Colored cord is designed for easy identification in a high density data environment.
This heavy duty 12 AWG power cord is fully molded for durability.
UL and cUL listed.
All relevant materials are complied with RoHS and REACH directive.
Shipping weight0.27 kg
Package size191 × 76 × 25 mm

Questions about this item

How do I connect the C20 and C19 ends to my PDU and server without forcing them?

Align the C20 plug with the PDU outlet and the C19 connector with the server inlet, then push each straight in until the moulded body seats fully; the keyed IEC-60320 shape prevents reverse insertion.

Will the SJT 12 AWG jacket need periodic replacement in a hot aisle?

The UL-listed SJT 12 AWG x 3C construction is rated for continuous 20 A at 250 V; inspect annually for discoloration, cracking or heat damage at the moulded connectors and replace if any appears.

At what load does the 6 ft cord hit its thermal limit first?

The 12 AWG conductors are rated for 20 A at 250 V; sustained operation at that full rating is the design limit, so monitor connector temperature when running near 20 A continuously.