We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

NavePoint

NavePoint CAT6 Riser CMR 1000 Ft Red 23AWG 250 MHz network ethernet cable

SKU CH-5CK9-CRWEG

Red CMR-rated CAT6 bulk cable delivers 250 MHz bandwidth over 1000 ft of solid 23 AWG bare copper for Gigabit indoor runs

  • TypeEthernet Crossover Raw
  • ColorRed
  • CMR riser rating meets fire safety codes for indoor runs
  • 23 AWG solid bare copper conductors deliver reliable signal integrity
  • 250 MHz tested bandwidth supports gigabit Ethernet performance
  • 1000 ft pull box with foot markings enables custom-length cuts
  • Red jacket colour simplifies cable identification in dense installs

Solid copper riser cable for structured wiring

This NavePoint CAT6 UTP cable uses 23 AWG solid bare copper conductors and a CMR-rated jacket. It is supplied in a 1000-foot pull box with footage markings every foot. The construction meets Category 6 specifications and is tested to 250 MHz.

Installers running vertical

The riser rating suits multi-floor pulls where plenum is not required, and the solid conductors terminate reliably on punch-down blocks and keystones. It is not for buyers who need stranded patch cords for frequent flexing, nor for outdoor or direct-burial routes.

250 MHz tested bandwidth on four unshielded pairs

This figure confirms the cable supports gigabit Ethernet and PoE loads over the full 100 metre channel. The 400 MHz claim in promotional material is not a warranted specification.

Highlights

  • CMR riser rating meets fire safety codes for indoor runs
  • 23 AWG solid bare copper conductors deliver reliable signal integrity
  • 250 MHz tested bandwidth supports gigabit Ethernet performance
  • 1000 ft pull box with foot markings enables custom-length cuts
  • Red jacket colour simplifies cable identification in dense installs

Specifications

BrandNavePoint
TypeEthernet Crossover Raw
ColorRed

Questions about this item

What conduit diameter is needed for the 23 AWG solid-core cable?

The 23 AWG solid bare copper conductors with CMR-rated jacket fit standard ¾-inch conduit runs; allow extra space for the four-pair bundle and pulling tension.

How is the pull-box used during a riser installation, and what mistake causes kinks?

Mount the box at the top of the run, feed cable downward, and maintain a wide bend radius; pulling from the box centre instead of the outer coils twists the pairs and creates permanent kinks.

When should the cable be re-certified or replaced in a PoE deployment?

Re-test to 250 MHz after any cable crush, water ingress, or after 10 years in high-heat PoE paths; replace if insertion loss exceeds the Category 6 limit at 250 MHz.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.