We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Meterk ATLLLAA3858 0.5-4.5V 60 Psi Pressure Transducer 1/8" NPT Stainless Steel

SKU CH-P24T-SYK1M

Measures 0-60 psi gauge pressure with 0.5-4.5 V linear output, 1/8" NPT stainless steel body, IP67 rated, Packard connector included

  • Voltage125VAC
  • Length2.5908 L x 12.446 W x 15.875 H centimeters
  • Accurate readings with ±0.5% full-scale precision
  • IP67-rated stainless steel resists dust and water ingress
  • 5–4.5 V linear output simplifies controller integration
  • Operates from −40 °C to +120 °C for harsh environments
  • 1 ms response time captures rapid pressure changes

Meterk ATLLLAA3858 pressure transducer

The Meterk ATLLLAA3858 is a stainless steel pressure transducer that converts 0 to 60 psi gauge pressure into a 0.5 to 4.5 V linear voltage signal. It operates from a 125 VAC supply and uses a 1/8 inch NPT thread for direct mounting in tanks or piping. The Packard plug-in connector simplifies wiring with colour-coded leads for power, ground and signal.

Suits fluid monitoring in industrial

Engineers monitoring oil, fuel, diesel, gas, water or air pressure in compatible 316L stainless steel media will find the IP67 rated sensor reliable from -40 to 120 °C. Buyers who need a different pressure range, a current loop output or a flange mounting style should look at alternative sensor types.

Handles 60 psi full scale

The transducer maintains ±0.5 % full scale accuracy and 1 ms response time across its range, with long term drift below 0.1 % FS per year. Temperature effects stay within 0.05 % FS per °C and the Exia IIC T6 explosion proof rating allows use in hazardous areas, but the fixed 0.5 to 4.5 V output cannot be re-scaled for other ranges.

Highlights

  • Accurate readings with ±0.5% full-scale precision
  • IP67-rated stainless steel resists dust and water ingress
  • 5–4.5 V linear output simplifies controller integration
  • Operates from −40 °C to +120 °C for harsh environments
  • 1 ms response time captures rapid pressure changes

Specifications

BrandMeterk
Voltage125VAC
Length2.5908 L x 12.446 W x 15.875 H centimeters
Part NumberATLLLAA3858

Questions about this item

What power supply must I already have to run the 0.5-4.5V output?

Provide a regulated 5 V DC source capable of at least 20 mA; the transducer draws its supply from the red wire and returns ground on the black wire.

Will the 1/8" NPT thread seal directly into my existing steel manifold?

Yes, the 1/8" NPT male thread mates with any standard 1/8" NPT female port; use PTFE tape or sealant rated for 316L stainless steel compatibility.

How do I verify the sensor is calibrated after installation?

Apply 0 psi and confirm 0.5 V on the green wire, apply 30 psi and confirm 2.5 V, apply 60 psi and confirm 4.5 V; linearity should stay within ±0.5 % FS.