Innovation First, Inc. 1UCMA-137 1U Cable Management Arm 19" 28.5"-33" computer accessory
- Product Type:Cable…
- Panel Width:19" Rac…
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Liebert
Hardwired 30 A PDU with maintenance bypass breaker for compatible 208 V UPS units
This power distribution unit delivers hardwired input and output connections rated at 30 A and 208 V. It is designed for data-centre and server-room operators who need to service a UPS without interrupting power to connected loads. The unit plugs directly into the rear of compatible Liebert GXT UPS models and provides six hardwire terminal-block outputs.
The integrated maintenance bypass breaker allows the entire UPS to be removed or replaced while critical equipment remains powered. This capability reduces downtime during scheduled maintenance or unexpected UPS failure and avoids the need for external bypass panels or additional wiring.
Both input and output use a three-wire-plus-ground hardwire terminal block, so the PDU must be installed by qualified electricians on a 30 A 208 V circuit. It is not suited for plug-and-play rack deployments or environments that require standard IEC or NEMA receptacles.
| Brand | Liebert |
|---|---|
| Model | PD2-HDWR-MBS |
| Features | Product Name:PD2-HDWR-MBS 6-Outlets PDU Output Receptacles:Hardwire Terminal Block 3W + G Product Type:PDU Current:30 A Input Receptacles:Hardwire Terminal Block 3W + G |
| Weight | 6.00 lb |
| Shipping weight | 3.63 kg |
| Package size | 533 × 249 × 241 mm |
The hardwire terminal block should be checked and retorqued during scheduled maintenance to ensure secure connections under continuous 30 A load.
The 30 A breaker and hardwire terminals set the sustained current limit; exceeding 30 A will trip the maintenance bypass breaker.
The PDU itself adds minimal heat; nearly all thermal load comes from the connected UPS and downstream equipment drawing up to 30 A at 208 V.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?