We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Liebert

Liebert PD2-106 PDU 8-Outlets 60A 4x L5-20R 4x L6-20R

SKU CH-20V3-CECSW MPN PD2-106

A 60 A power distribution unit with four NEMA L5-20R and four NEMA L6-20R outlets, hardwire three-wire-plus-ground input, weighing 6.60 lb

  • TypeConsumer Electronics
  • FeaturesProduct Name:PD2-106 8-Outlets PDU Output Receptacles:4 x NE
  • Weight6.60 lb
  • 8 outlets deliver flexible power distribution
  • 60 A rating supports high-density rack loads
  • Hardwire 4-wire input enables direct panel connection
  • Four L5-20R and four L6-20R receptacles mix voltages
  • 60 lb weight simplifies rack mounting

PDU for GXT4 8-10kVA UPS

The Liebert PD2-106 is a power distribution unit built for Vertiv GXT4 UPS models rated 8 to 10 kVA. It provides a maintenance bypass so connected equipment stays powered while the UPS is serviced. The unit accepts a hardwired 4-wire input and distributes power through eight locking receptacles. It suits data-centre and critical-infrastructure operators who need continuous uptime during UPS maintenance.

Installation and common issues

The PDU mounts in a standard rack and connects via a hardwire terminal block with three wires plus ground. A qualified electrician must terminate the 60 A feed to meet local code. The four NEMA L5-20R and four NEMA L6-20R outlets accept locking plugs that resist accidental disconnection. Mis-wiring the two-phase input or exceeding the 20 A per receptacle rating are the typical errors that cause nuisance tripping or overload.

60 A two-phase input rating

The single specification that decides fit is the 60 A, 4-wire (2PH+N+G) hardwire input. Your upstream breaker, wiring and UPS frame must all support this exact current and phase configuration. If the site supply is single-phase, three-phase or rated below 60 A, this PDU cannot be used. No other current or phase arrangement is compatible.

Highlights

  • 8 outlets deliver flexible power distribution
  • 60 A rating supports high-density rack loads
  • Hardwire 4-wire input enables direct panel connection
  • Four L5-20R and four L6-20R receptacles mix voltages
  • 60 lb weight simplifies rack mounting

Specifications

BrandLiebert
ModelPD2-106
TypeConsumer Electronics
FeaturesProduct Name:PD2-106 8-Outlets PDU
Output Receptacles:4 x NEMA L5-20R
4 x NEMA L6-20R
Number of Output Connections:4
Product Type:PDU
Current:60 A
Input Receptacles:Hardwire Terminal Block 3W + G
Weight6.60 lb
Shipping weight4.23 kg
Package size524 × 304 × 221 mm

Questions about this item

How do I confirm the PD2-106 is operating correctly after hardwiring the 60 A input?

Verify the unit powers on and each of the eight receptacles delivers voltage matching its NEMA rating; the maintenance bypass should transfer load to utility without interruption when engaged.

What ships with the PD2-106 and what must I source separately?

The PDU itself includes the hardwire terminal block for 3W + G input and eight output receptacles (four L5-20R, four L6-20R); input cable, conduit, breakers and mounting hardware are not supplied.

Should I choose the PD2-106 for a 10 kVA GXT4 UPS or is another capacity needed?

The PD2-106 is listed for GXT4 8-10 kVA models and provides 60 A through four L5-20R and four L6-20R outlets; match the UPS kVA rating to this range.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.