We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Liebert

Liebert PD2-104 PDU 60A 4×5-20R 2×L6-30R 2×L6-20R

SKU CH-AYD5-JWBR4 MPN PD2-104

Distributes power through eight mixed NEMA outlets from a 60 A hardwired input with maintenance bypass for GXT4 UPS units

  • TypeConsumer Electronics
  • FeaturesProduct Name:PD2-104 8-Outlets PDU Output Receptacles:2 x NE
  • Weight6.60 lb
  • Eight mixed outlets support diverse equipment
  • 60 A hard-wire input feeds high-density racks
  • Maintenance bypass enables hot-swap UPS service
  • Designed for GXT4 8-10 kVA units
  • Weighs 6.60 lb for easy mounting

Output distribution

This power distribution unit provides eight receptacles for connecting equipment to a Vertiv Liebert GXT4 8-10kVA UPS. It accepts a hardwired 60 A input and delivers power through four NEMA 5-20R, two NEMA L6-20R and two NEMA L6-30R outlets. The unit mounts in the rear of the UPS to convert the output wiring to a plug-and-play configuration.

Installers needing hot-swap UPS maintenance

The integrated maintenance bypass lets technicians remove or replace the UPS without cutting power to connected loads. Sites that require only hardwired output connections or a different receptacle mix should select an alternative POD model. Facilities without a compatible GXT4 8-10kVA UPS cannot use this unit.

60 A hardwired input rating

The PDU is rated for a 60 A, 4-wire (2PH+N+G) hardwire feed that matches the UPS input specification. This single electrical rating determines whether the unit can be safely installed on the available supply circuit.

Highlights

  • Eight mixed outlets support diverse equipment
  • 60 A hard-wire input feeds high-density racks
  • Maintenance bypass enables hot-swap UPS service
  • Designed for GXT4 8-10 kVA units
  • Weighs 6.60 lb for easy mounting

Specifications

BrandLiebert
ModelPD2-104
TypeConsumer Electronics
FeaturesProduct Name:PD2-104 8-Outlets PDU
Output Receptacles:2 x NEMA L6-20R
2 x NEMA L6-30R
4 x NEMA 5-20R
Number of Output Connections:2
4
Product Type:PDU
Current:60 A
Input Receptacles:Hardwire Terminal Block 3W + G
Weight6.60 lb
Shipping weight4.08 kg
Package size520 × 310 × 220 mm

Questions about this item

What maintenance does the PD2-104 bypass switch require over time?

The maintenance bypass enables hot-swapping the UPS without power interruption; the unit itself has no user-serviceable parts and needs no scheduled maintenance beyond standard electrical inspections.

Which receptacle rating reaches its limit first when the PD2-104 runs at full 60 A load?

The two NEMA L6-30R outlets are each rated for 30 A, so they hit their per-receptacle limit before the 20 A outlets or the overall 60 A feed.

How much heat and noise does the PD2-104 add when installed in a GXT4 UPS running continuously?

The PD2-104 is a passive distribution box with no fans or active components, so it adds no audible noise and negligible heat beyond normal conductor losses.