We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Liebert

Liebert MicroPOD Maintenance Bypass Panel 2 kVA Rack-mountable Hardwired

SKU CH-MF7Z-SNEHH

Maintenance bypass switch enables UPS servicing without interrupting power to critical 2 kVA rack-mounted loads via hardwired connections

  • Uninterrupted power during UPS service via manual bypass switch
  • 2 kVA load capacity supports critical equipment
  • Hardwired receptacles for permanent installation
  • Rack-mountable form factor fits standard enclosures
  • Simple rotary switch transfers load between utility and UPS power

Maintenance Bypass Panel 2 kVA

The Liebert MicroPOD is a rack-mountable maintenance bypass and power output distribution switch rated for 2 kVA. It enables manual transfer of connected equipment to utility power so that UPS servicing or replacement can occur without interrupting the critical load. The unit uses hardwired connections for integration into existing power infrastructure. It is designed for environments where continuous uptime is required during maintenance windows.

Suited For And Not Suited For

This panel suits data centres, server rooms and network closets that operate a compatible Liebert UPS and need zero-downtime maintenance capability. It is not intended for standalone power protection or surge suppression without a UPS. Installations lacking hardwired electrical provisioning or those requiring plug-and-play receptacle connectivity will not be able to use this model. Buyers needing automatic transfer switching or remote management features should look elsewhere.

Capacity And Headroom

The 2 kVA rating defines the maximum apparent power the bypass can handle while maintaining the load on utility power. Within this limit the switch comfortably supports routine UPS battery replacement, firmware updates or full unit swap-outs. Loads exceeding 2 kVA will overload the bypass path and risk transfer failure. The hardwired design provides no additional receptacle headroom beyond the installed circuit capacity.

Highlights

  • Uninterrupted power during UPS service via manual bypass switch
  • 2 kVA load capacity supports critical equipment
  • Hardwired receptacles for permanent installation
  • Rack-mountable form factor fits standard enclosures
  • Simple rotary switch transfers load between utility and UPS power

Specifications

BrandLiebert

Questions about this item

What UPS capacity is required for the MicroPOD 2 kVA bypass panel to handle my critical load?

The panel supports a 2 kVA load, so the connected UPS must be rated at 2 kVA or higher to carry the full load during normal operation.

Can the hardwired MicroPOD panel integrate with my existing rack-mount UPS that uses IEC outlets?

Yes, the panel is rack-mountable and hardwired; an electrician can terminate its wiring to match your UPS input and output conductors regardless of the UPS receptacle type.

How do I verify the MicroPOD is correctly feeding utility power to my servers during a maintenance bypass?

Turn the rotary switch to the bypass position and confirm the load remains powered; the switch mechanically isolates the UPS while maintaining continuity to the critical equipment.