We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Liebert

Liebert GXT4-6000RTL630 6000VA 4200W UPS

SKU CH-CCJH-D0W11 MPN GXT4-6000RTL630

True on-line double-conversion UPS delivers 6000 VA / 4200 W continuous power to IT equipment with zero transfer time to battery

  • Input Voltage Range208 V
  • Input ConnectionL6-30P
  • VA Rating6000 VA
  • Watts4200 W
  • Output Voltage208 V
  • Outlets4
  • True on-line double-conversion power with zero transfer time
  • 6000 VA / 4200 W capacity supports dense IT loads
  • Rack or tower installation with included slide kit
  • Four locking outlets: two L6-30R and two L6-20R
  • LCD panel shows load, voltage, alarms and battery status

6000VA 4200W On-Line UPS

The Liebert GXT4-6000RTL630 is a true on-line, double-conversion UPS rated at 6000 VA and 4200 W. It delivers continuous, high-quality AC power to IT equipment with no break when transferring to battery power. The unit protects connected devices from blackouts, brownouts, sags, surges, frequency deviations and noise interference. It is suited for server rooms and network closets requiring high availability.

Rack or Tower Mount with L6-30P Input

This model installs in either a rack or tower configuration and includes a rack slide kit for 18 to 32 inch racks. Input power connects via a NEMA L6-30P plug operating at 208 V. Output receptacles comprise two L6-30R and two L6-20R outlets, providing four total connections for critical loads. An optional POD with L6-30P input and L6-30R output allows maintenance without powering down equipment. The LCD panel displays load percentage, system voltages, alarm notifications and battery capacity.

Intelligent Fan and Double-Conversion Efficiency

Intelligent fan operation automatically adjusts fan speed to decrease power consumption and acoustic noise during normal operation. The double-conversion topology isolates connected equipment from all input power disturbances while maintaining a high power factor. Internal batteries are included and the unit ships on an individual pallet. An SNMP web card is supplied for remote monitoring and management. Buyers needing extended runtime beyond the internal battery or output voltages other than 208 V should consider alternative configurations.

Highlights

  • True on-line double-conversion power with zero transfer time
  • 6000 VA / 4200 W capacity supports dense IT loads
  • Rack or tower installation with included slide kit
  • Four locking outlets: two L6-30R and two L6-20R
  • LCD panel shows load, voltage, alarms and battery status

Specifications

BrandLiebert
ModelGXT4-6000RTL630
Input Voltage Range208 V
Input ConnectionL6-30P
VA Rating6000 VA
Watts4200 W
Output Voltage208 V
Outlets4
Outlet Type2 x L6-30R
2 x L6-20R
FeaturesThe Liebert GXT4-6000RTL630 Rack/Tower UPS is a true on-line UPS with a 6000VA/4200W power capacity that delivers continuous, high-quality AC power to IT equipment with no break when transferring to battery power. It protects equipment from all power disturbances such as but not limited to blackouts, brownouts, sags, surges, frequency deviations, or noise interference. Features: Installs in either rack or tower configuration. Includes rack slide kit (RMKIT18-32), internal battery, and SNMP web card (IS-WEBCARD). Unit ships on individual pallet. Intelligent fan operation, automaticall
Shipping weight74.84 kg
Package size843 × 622 × 340 mm

Questions about this item

What input plug does the GXT4-6000RTL630 use, and what voltage does it accept?

The unit connects with an L6-30P plug and operates on a 208 V input supply.

Which rack-mount kit is included, and what rack depths does it cover?

The supplied RMKIT18-32 slide kit fits racks from 18 to 32 inches deep.

How do I set up the bundled SNMP web card so the UPS appears on the network?

Insert the IS-WEBCARD into the intelligent slot, power the UPS, then configure the card's IP address through its web interface or the front-panel LCD menu.