Innovation First, Inc. 1UCMA-137 1U Cable Management Arm 19" 28.5"-33" computer accessory
- Product Type:Cable…
- Panel Width:19" Rac…
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Intellinet Network Solutions
Connects LC and SC equipment with OM4 multimode fiber rated for 10G, 40G and 100G Ethernet, using bend-insensitive 50/125 µm Corning glass and UPC polish for low loss
This 5 m duplex patch cable uses OM4 multimode fiber with LC and SC UPC connectors. The aqua jacket identifies the OM4 grade and the 50/125 µm core/cladding dimensions. Bend-insensitive Corning glass reduces attenuation when the cable is routed around tight corners. A factory test report ships with every unit.
Suited for cross-connect and interconnect runs in entrance facilities, telecom rooms and data centers where 10 G, 40 G or 100 G Ethernet is deployed. Not intended for single-mode infrastructure or for outdoor plant installations that require OS2 cable. Buyers needing APC polished ferrules or a different connector combination should select another part.
The OM4 multimode core delivers the bandwidth headroom required for 40 G and 100 G Ethernet over the 5 m reach. UPC finish on both connectors provides low return loss for stable links. The 2.0 mm jacket meets OFNR fire rating for indoor riser use.
| Brand | Intellinet Network Solutions |
|---|---|
| Model | OM4 Multimode Duplex |
| Type | Fiber |
| Connector A | LC |
| Connector B | SC |
| Length | 5 m |
| Color | Aqua Blue |
| Shielded | No |
| Features | 50/125 µm, Bend Insensitive Multimode Fiber (BIMMF), UPC |
The 2.0 mm duplex jacket is sized for standard LC and SC patch-panel cut-outs, so it routes through typical panel openings without force.
Push each connector straight in until the latch clicks; the step often skipped is cleaning the ferrule end-face with a lint-free wipe and isopropyl alcohol before insertion.
Replace the cable if a later insertion-loss test shows loss exceeding the original test-report baseline, or if the aqua jacket shows kinks, cracks or connector ferrule damage.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?