iMBAPrice
iMBAPrice 1 ft 10 Pack Cat6 Shielded Patch Cable Blue
Ten 1 ft Cat6 shielded patch cables with double shielding and gold-plated RJ45 plugs for 10 Gigabit Ethernet
- TypeCable
- Supports 10GBASE-T over 100 metre runs
- Double foil-and-braid shielding blocks interference
- 26 AWG stranded bare copper ensures signal integrity
- 50 µm gold-plated RJ45 plugs resist corrosion
- UL listed and RoHS compliant for safety
10-pack Cat6 shielded patch cables
This ten-piece set supplies one-foot shielded Cat6 patch cables for short rack or desk connections. Each cable uses 26 AWG stranded bare copper conductors with double shielding — foil around every pair plus an overall braid — and gold-plated shielded RJ45 plugs. The moulded snagless boots protect the latch during repeated insertion and removal.
Shielding, materials and compliance
Double shielding and bare copper construction keep alien crosstalk low and meet the proposed Cat6A channel requirements of TIA/EIA-568-B.2-10, ISO/IEC 11801, CENELEC EN 50173 and IEEE 802.3 an. The cables are UL listed and RoHS compliant, with 50 micron gold contacts that resist corrosion in normal office or data-centre environments.
Supported applications and distance limits
Qualified for frequencies up to 500 MHz, the cables support 10GBASE-T over the full 100 metre channel as well as 1000BASE-T, 100BASE-TX, 10BASE-T, ATM at 155 and 622 Mbps, Token Ring at 4 and 16 Mbps, 100VG-AnyLAN and 100 Mbps TP-PMD. They are not suited for runs that exceed the 100 metre channel limit or for installations requiring unshielded or solid-conductor cable.
Highlights
- Supports 10GBASE-T over 100 metre runs
- Double foil-and-braid shielding blocks interference
- 26 AWG stranded bare copper ensures signal integrity
- 50 µm gold-plated RJ45 plugs resist corrosion
- UL listed and RoHS compliant for safety
Specifications
| Brand | iMBAPrice |
|---|---|
| Type | Cable |
Questions about this item
How do I install the 1 ft Cat6 shielded patch cable and what step do people often miss?
Plug each RJ45 connector firmly until the latch clicks; the step often missed is verifying both ends lock so the shielded path stays continuous.
What maintenance or replacement will the 10-pack of Cat6 shielded cables need later?
Inspect the 50 micron gold-plated contacts and double-shielded jackets periodically; replace any cable with damaged boots or corroded pins.
What limit appears first on the 1 ft Cat6 shielded cable under sustained 10GBASE-T use?
The 500 MHz bandwidth ceiling and 100 metre channel limit for 10GBASE-T define the first performance boundary.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



