HUBBELL WIRING DEVICE-KELLEMS HBLDS3SSVFD Motor Disconnect Switch
Non-fusible motor disconnect switch meeting NEC 430.102(B) line-of-sight requirements
- Meets NEC 430.102(B) motor-disconnect code requirements
- UL-listed manual motor controller ensures safe operation
- Circuit-Lock unfused design simplifies installation and maintenance
- Suitable as motor disconnect for driven equipment
- Hubbell Wiring Device-Kellems brand delivers reliable industrial quality
Motor Disconnect Switch for Code Compliance
The Hubbell Circuit-Lock unfused disconnect switch serves as a manual motor controller and satisfies NEC section 430.102(B) requirements for a disconnect within sight of the motor. It is intended for industrial maintenance teams and electrical contractors wiring motor-driven equipment.
Installation and Common Issues
The switch mounts in a standard enclosure and connects with conventional wiring methods for motor circuits. The most frequent issue is selecting a fused model when the application only calls for an unfused disconnect, or overlooking the line-of-sight placement rule during layout.
NEC 430.102(B) Listed Disconnect
This device carries a UL listing as a manual motor controller and is marked suitable as a motor disconnect per the cited code section. Buyers needing integrated over-current protection or a fused disconnect should specify a different product.
Highlights
- Meets NEC 430.102(B) motor-disconnect code requirements
- UL-listed manual motor controller ensures safe operation
- Circuit-Lock unfused design simplifies installation and maintenance
- Suitable as motor disconnect for driven equipment
- Hubbell Wiring Device-Kellems brand delivers reliable industrial quality
Specifications
| Brand | HUBBELL WIRING DEVICE-KELLEMS |
|---|
Questions about this item
How do I verify the switch meets NEC 430.102(B) after installation?
Confirm the switch is mounted within sight of the motor and driven equipment, then check the UL listing label on the enclosure showing it is listed as a manual motor controller and suitable as a motor disconnect.
What components come with the HBLDS3SSVFD and what must I source separately?
The switch ships as a complete non-fusible disconnect enclosure; you supply the mounting hardware, wiring, conduit fittings and any required overload protection.
Which version of this disconnect should I choose for a standard motor circuit?
The HBLDS3SSVFD is a single non-fusible Circuit-Lock model rated for manual motor controller and motor disconnect use; select it when code requires a sight‑line disconnect without integrated fuses.