We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Hubbell Incorporated

Hubbell Incorporated RACO 3423 90 Degree Liquidtight Conduit Connector 3/4 in Steel Electro Zinc

SKU CH-R25E-NJ8TP

Connects 3/4 inch liquidtight conduit at a 90 degree angle with a split gland-ring seal for hazardous locations

  • TypeCable Management & Conduit
  • 90-degree elbow routes conduit around tight corners
  • split gland-ring seals against moisture and prevents pull-out
  • zinc-electroplated steel resists corrosion in indoor or outdoor use
  • approved for Class I Div 2 and Class II/III hazardous locations
  • sealing washer and heavy-duty locknut included for secure box connection

3/4-inch 90° Liquidtight Conduit Connector

The RACO 3423 connects 3/4-inch flexible metallic or Type B nonmetallic liquidtight conduit to a box or enclosure at a right angle. It is built for electricians and installers working in commercial or industrial environments where moisture, oil, or dust are present. The fitting is rated for new installations in hazardous locations including Class I Div 2, Class II Div 1 and 2, and Class III Div 1 and 2. It is not for rigid conduit systems or applications requiring an insulated throat.

Innovative Split Gland-Ring Seal

The connector features an innovative split gland-ring designed to create a perfect seal around the conduit jacket while preventing pull-out under tension. This single mechanical feature determines whether the fitting will maintain its liquidtight integrity in vibration-prone or wet locations. A sealing washer and heavy-duty locknut are included to complete the termination at the enclosure. All components are reusable, allowing the fitting to be disassembled and reinstalled if routing changes are required.

Zinc-Electroplated Steel for Corrosion Resistance

The steel body receives an electro-zinc plating that provides corrosion protection for both indoor and outdoor exposure. The uninsulated, all-metal construction adds no significant thermal resistance and generates no acoustic noise during operation. Power draw is not applicable to this passive mechanical fitting. The connector adds negligible weight or bulk to the raceway system.

Highlights

  • 90-degree elbow routes conduit around tight corners
  • split gland-ring seals against moisture and prevents pull-out
  • zinc-electroplated steel resists corrosion in indoor or outdoor use
  • approved for Class I Div 2 and Class II/III hazardous locations
  • sealing washer and heavy-duty locknut included for secure box connection

Specifications

BrandRACO
TypeCable Management & Conduit

Questions about this item

How does the 90 degree bend affect cable routing inside a cabinet?

The 90 Degree Liquidtight Connector lets flexible metallic or Type B nonmetallic conduit turn a right angle into a box or enclosure while maintaining a liquidtight seal.

What conduit types does the 3423 connector accept and what rating does it carry?

It fits flexible metallic liquidtight conduit and Type B flexible nonmetallic liquidtight conduit, and is rated for Class I Div 2, Class II Div 1 & 2, and Class III Div 1 & 2 hazardous locations.

What hardware is included for mounting the 3/4 in steel connector to an enclosure?

A sealing washer and heavy-duty locknut are supplied, and the split gland-ring design creates a positive bond that resists pullout.