Hubbell Incorporated
Hubbell Incorporated RACO 2156 EMT/IMC Coupling 4 in Set Screw Steel Plain Gray
Joins 4 in EMT, IMC or RMC conduit with a set-screw steel coupling measuring 4 23/32 in long and 4 25/32 in high and wide, weighing 2.57 lb and UL Listed for concrete-tight straight connections
- TypeCable Management & Conduit
- UL Listed for safety compliance
- Set screw connection enables fast installation
- Concrete tight rating protects wiring in wet locations
- Fits 4 in EMT, IMC and RMC conduit
- Weighs 2.57 lb for solid steel construction
RACO 2156 Set-Screw Conduit Coupling
This steel coupling joins two 4-inch trade-size EMT, IMC or RMC conduits in a straight line. The set-screw connection secures each pipe without threading tools. UL listed and concrete-tight, it suits commercial and industrial raceway installations. The plain gray finish matches standard conduit appearance.
4-Inch Trade Size and Set-Screw Connection
The coupling accepts conduit with a 4-inch trade size and uses set screws to lock each length in place. Overall length is 4 23/32 inches with an overall height and width of 4 25/32 inches. This single dimension determines whether the fitting matches the raceway being installed.
Steel Body Sustains Mechanical Load
The steel body resists deformation when conduit runs are pulled tight or subjected to vibration. At 2.57 lb the fitting adds mass that helps dampen movement in long straight sections. Concrete-tight rating means the joint maintains integrity when embedded in poured slabs.
Highlights
- UL Listed for safety compliance
- Set screw connection enables fast installation
- Concrete tight rating protects wiring in wet locations
- Fits 4 in EMT, IMC and RMC conduit
- Weighs 2.57 lb for solid steel construction
Specifications
| Brand | RACO |
|---|---|
| Type | Cable Management & Conduit |
Questions about this item
What does the 4 in trade size mean once the coupling is installed on conduit?
It joins two runs of 4 in EMT, IMC or RMC conduit in a straight line using set screws for a concrete-tight connection.
What does the UL Listed standard cap in practice for this coupling?
UL Listing confirms the fitting meets safety requirements for use with EMT, IMC and RMC conduit in electrical installations.
What clearance is needed to fit the 4 25/32 in overall height and width?
Allow at least 4 25/32 in of space in both height and width for the coupling body, plus room to tighten the set screws.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.