Hetai Tech
Hetai Tech YYI-2 5-24V DC Current Sensor Relay Board
Detects DC current from 0 to 10 A with 0.01 A accuracy and switches loads up to 5 A via relay
- Detects DC current up to 10 A with 0.01 A accuracy
- Relay switches loads up to 5 A on the same DC line
- Seven programmable protection modes cover over-current, under-current and window limits
- Error calibration and display-off option cut standby draw to about 20 mA
- Operates from a single 5–24 V DC supply without extra regulators
DC Current Sensor Relay Board
The Hetai Tech YYI-2 module monitors DC current from 0 to 10 amps with 0.01 amp accuracy across a 5 to 24 volt supply range. It suits makers adding overcurrent protection or motor-blocking logic to low-voltage projects.
Detection limited to 10 amps
The onboard sensor cannot measure currents above 10 amps, and the relay output only controls DC lines up to 5 amps. Builders needing higher load switching or wider measurement range must look elsewhere.
Seven programmable protection modes
Modes P-11 through P-41 define how the relay reacts when current crosses the two user-set thresholds I1 and I2, including latch-on and window-comparator behaviours. Selecting the correct mode decides whether the board fits the application.
Highlights
- Detects DC current up to 10 A with 0.01 A accuracy
- Relay switches loads up to 5 A on the same DC line
- Seven programmable protection modes cover over-current, under-current and window limits
- Error calibration and display-off option cut standby draw to about 20 mA
- Operates from a single 5–24 V DC supply without extra regulators
Specifications
No published specifications for this item yet.
Questions about this item
Which version of the YYI-2 board should I choose for a 12 V DC system?
The board operates from 5-24 V DC, so it works directly on a 12 V supply without any extra step-down or step-up converter.
What does the 10 A detection range mean when the relay is only rated for 5 A switching?
The sensor can measure up to 10 A, but the onboard relay will only switch loads up to 5 A; for higher currents you must use the relay to drive an external contactor.
How does the 0.01 A accuracy affect the over-current threshold I can set?
You can programme the trip points I1 and I2 in 10 mA steps, giving fine control over when the relay opens or closes.
New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Tripp Lite N262 014 BL Cat6a Shielded 10G Patch Cable 14ft Blue accessories barebone
Intel HNS2600KPF barebone pc 1U dual Xeon DDR4 512 GB
- Xeon
- Socket R3 (LGA2011-…