We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

GreenTechLLC

GreenTechLLC APCRBCV206 24V 7Ah Battery Cartridge #206

SKU CH-BTHB-0PVK7

24 V sealed-lead-acid cartridge fits APC Easy UPS SMV1000CAI and SMVS1000CAI, replacing RBC206 with two 12 V 7 Ah cells ready to install

  • Battery Run Time1 - 30 minutes
  • Battery Recharge Time<24 Hour
  • Ready backup power for up to 30 minutes
  • Recharges fully in under 24 hours
  • Direct fit for APC Easy UPS SMV1000CAI and SMVS1000CAI
  • Pre-tested, charged and ready to install
  • Compact 5.95 x 5.15 x 3.75 inch cartridge

Compatible Replacement Cartridge

This sealed lead-acid battery cartridge replaces APC part APCRBCV206 for Easy UPS models SMV1000CAI and SMVS1000CAI. It arrives tested, charged and ready to install so the UPS can be returned to service immediately.

Runtime and Recharge Profile

The cartridge supplies between 1 and 30 minutes of backup power depending on the connected load. A full recharge completes in less than 24 hours, allowing the UPS to recover quickly after an outage.

24 Volt Dual-Block Configuration

Two 12 V 7 Ah blocks wired in series deliver the required 24 V output with F2 terminals. The assembly measures 5.95 by 5.15 by 3.75 inches and will not fit UPS units that require a different voltage, capacity or terminal type.

Highlights

  • Ready backup power for up to 30 minutes
  • Recharges fully in under 24 hours
  • Direct fit for APC Easy UPS SMV1000CAI and SMVS1000CAI
  • Pre-tested, charged and ready to install
  • Compact 5.95 x 5.15 x 3.75 inch cartridge

Specifications

Battery Run Time1 - 30 minutes
Battery Recharge Time<24 Hour

Questions about this item

How do I install the cartridge in an APC Easy UPS SMV1000CAI or SMVS1000CAI, and what step is often missed?

Power off and unplug the UPS, open the battery door, disconnect the old cartridge, connect the new F2 terminals observing polarity, slide the cartridge in until it clicks, close the door, then power on and let the UPS charge for up to 24 hours before relying on backup runtime.

What maintenance will this 24 V 7 Ah cartridge need, and when should I plan a replacement?

It is a sealed lead-acid unit requiring no watering; plan to replace it after three to five years or when the UPS reports a replace-battery warning and runtime drops below the 1 to 30 minute range.

What is the first limit I will hit during a long power cut with this cartridge?

The runtime limit of 1 to 30 minutes depending on load; once the battery is depleted the UPS will shut down until mains power returns and recharges the pack.