Fans
Fans W4D630-GD01-01 inverter cabinet fan
An axial cabinet fan with ball bearings runs at 1320 rpm on 400 V three-phase power, drawing 4.78 A at 2630 W and producing 220 Pa back pressure while rated for ambient temperatures from -40 °C
- German-engineered axial fan for reliable cabinet cooling
- Three-phase 400 V motor delivers 2630 W at 50 Hz
- Ball-bearing design ensures long service life at full speed
- Operates from -40 °C to 60 °C ambient temperatures
- Low starting current of 6.5 A reduces electrical stress
Inverter cabinet fan for industrial enclosures
The W4D630-GD01-01 is a three-phase axial fan built for inverter cabinets and similar enclosures. It operates on a 400 VAC supply at 50 Hz and uses ball bearings for extended service life. The unit is rated for ambient temperatures from -40 °C to 60 °C.
Three-phase power and mounting clearance
This fan requires a three-phase 400 VAC connection in a Y configuration and draws 4.78 A at the 1320 min⁻¹ speed setting or 2.95 A at 1050 min⁻¹. Starting current reaches 19 A or 6.5 A depending on the speed. Installers must provide the correct supply and ensure the cabinet allows unrestricted axial airflow.
Thermal range and power profile
Power input is 2630 W at the higher speed and 1750 W at the lower speed, with maximum back pressures of 220 Pa and 140 Pa respectively. The motor’s maximum safe operating speed is 1670 min⁻¹ at 70 °C. Ball bearings support continuous operation across the full temperature range.
Highlights
- German-engineered axial fan for reliable cabinet cooling
- Three-phase 400 V motor delivers 2630 W at 50 Hz
- Ball-bearing design ensures long service life at full speed
- Operates from -40 °C to 60 °C ambient temperatures
- Low starting current of 6.5 A reduces electrical stress
Specifications
No published specifications for this item yet.
Questions about this item
Will the 4.78 A current draw at 400 VAC limit continuous operation?
The fan draws 4.78 A at 400 VAC and 50 Hz in its primary operating point, delivering 2630 W input power at 1320 min⁻¹.
How hot and loud does the M4D138-LA motor get running all day at 1320 min⁻¹?
Ball bearings and a maximum ambient of 60 °C allow sustained operation; the motor is rated for 1670 min⁻¹ at 70 °C, so 1320 min⁻¹ runs within thermal limits.
Does the cabinet need a three-phase 400 VAC supply with a star connection for this W4D630-GD01-01?
Yes, the motor is a 3-phase 400 VAC Y-connected unit requiring a 50 Hz three-phase mains feed.