Fans AFB0412SHBDimensions 40mm 12V 0.35A server accessory
A 40 mm axial cooling fan with double ball bearings, 12 V power and 11000 r.p.m. rated speed
- FeaturesAFB0412SHB
- 40 × 40 × 15 mm footprint fits tight 1U bays
- 12 V DC input with 7 V–13.8 V range suits varied rails
- 11 000 RPM airflow clears dense server heat loads
- Double ball bearing rated 40 000 hours at 25 °C
- −10 °C to 70 °C operating span handles harsh rack environments
40 mm 12 V server cooling fan
The Delta AFB0412SHB is a 40 mm axial fan designed for server and workstation chassis. It runs on 12 V DC with a nominal current of 0.35 A and spins at 11000 r.p.m. The double ball bearing is rated for 40000 hours at 25 °C.
Replaces worn 4015 form-factor fans
This unit fits the 40 x 40 x 15 mm footprint used in many rackmount and blade systems. The jump is worth it when the original fan has exceeded its L10 life rating or developed bearing noise. The wide voltage range of 7 V to 13.8 V allows speed control via PWM or voltage regulation.
Check mounting holes and connector pinout
Verify that your chassis uses the standard 40 mm square mounting pattern and that the power connector matches the existing header. Ensure the operating ambient temperature stays within -10 °C to 70 °C. Confirm the airflow direction suits the server’s thermal design.
Highlights
- 40 × 40 × 15 mm footprint fits tight 1U bays
- 12 V DC input with 7 V–13.8 V range suits varied rails
- 11 000 RPM airflow clears dense server heat loads
- Double ball bearing rated 40 000 hours at 25 °C
- −10 °C to 70 °C operating span handles harsh rack environments
Specifications
| Features | AFB0412SHB |
|---|
Questions about this item
What are the exact dimensions of this fan so I can check it fits my server chassis?
The fan measures 40 × 40 × 15 mm, matching the 40 mm square footprint used in many server trays.
How do I connect the AFB0412SHB to a 12 V power source and which polarity should I observe?
It runs on DC 12 V with a 7 V to 13.8 V range; connect the red lead to positive and black to negative to avoid damage.
When should I expect to replace the AFB0412SHB under continuous operation?
The double ball bearing is rated for 40,000 hours at 25 °C, so plan replacement around that interval in typical server environments.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
LaCie STHT8000800 8TB RAID subsystem USB 3.1 Type C RAID 0 1
- USB 3.1 Type C
- 0, 1
SanDisk Professional SDPH34H-024T-NBAAB 24TB RAID enclosure
- Thunderbolt 3 and U…