Fans
Fans 6SY7000-0AF09 280 mm 230 VAC centrifugal case fan
Centrifugal case fan with a 280 mm impeller running at 2740 RPM, delivering 2565 m3/h airflow at 81 dB(A) on 230 VAC
- Delivers 2565 m³/h airflow for high-volume cooling
- Runs on 230 VAC single-phase power for direct mains connection
- Operates from -20 °C to 60 °C for wide temperature tolerance
- Built with galvanised steel impeller and metal external rotor motor for durability
- Rated at 81 dB(A) noise level for audible performance reference
Industrial cooling for high-power converters
This 280 mm centrifugal case fan is built for 230 VAC single-phase supplies and targets integrators maintaining Xerox 100 equipment or similar industrial enclosures. It delivers 2565 m3/h of airflow at 890 W input power, driven by a metal external-rotor motor that reaches 2740 rpm. The galvanised steel impeller and IP10 rating suit protected indoor cabinets where high static pressure up to 850 Pa is required.
Wiring and mounting considerations
The fan terminates in a TR64 plug with 400 mm bare leads, so the installer must provide a compatible receptacle and route cables within the enclosure. A 12.0 uF 450 V start capacitor is specified and must be sourced separately if not already present in the converter circuit. Operating voltage range spans AC 190 V to 245 V at 60 Hz, and the unit weighs 7.2 kg, requiring secure mechanical fixing. No PWM or speed-control interface is provided.
Replacement guidance for aging units
This model directly replaces a failed 6SY7000-0AF09 fan when noise has risen toward the 81 dB(A) rating or airflow has dropped below the 2565 m3/h spec. The L10 life expectancy of 30 000 hours at 40 °C gives a predictable service interval for preventive swaps. It is not suited for low-voltage DC chassis, noise-sensitive workstations or builds needing variable-speed control, and it lacks the certifications or connectors for consumer PC cases.
Highlights
- Delivers 2565 m³/h airflow for high-volume cooling
- Runs on 230 VAC single-phase power for direct mains connection
- Operates from -20 °C to 60 °C for wide temperature tolerance
- Built with galvanised steel impeller and metal external rotor motor for durability
- Rated at 81 dB(A) noise level for audible performance reference
Specifications
No published specifications for this item yet.
Questions about this item
What is the first limit reached during sustained operation, the 60 °C ambient cap or the 30 000-hour L10 life at 40 °C?
The 30 000-hour L10 life at 40 °C is the first limit; running hotter than 40 °C shortens life before the 60 °C absolute ambient ceiling is hit.
How loud and how much heat does the 890 W motor add when running all day?
It produces 81 dB(A) and exhausts roughly 890 W of heat into the cabinet, so plan for active ventilation.
Which mating connector must I already have for the TR64 bare-lead plug on the 400 mm cable?
You need a TR64 receptacle or terminal block that accepts the bare ends of the 400 mm winding-coil outlet.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.