We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton PW103BA1U405 1U Horizontal PDU 16A 16×C13 3.33kVA

SKU CH-EA1C-HQ0D0 MPN PW103BA1U405

Distributes power across 16 C13 outlets from a single C20 inlet, rated 16 A and 3.33 kVA in a 1U horizontal chassis

  • TypeConsumer Electronics
  • Input Voltage100V AC to 240V AC Single-phase
  • FeaturesNumber of Output Connections: 16 Current: 16A Input Current
  • Dimensions1.70" x 19.00" x 7.00"
  • Distributes up to 3.33 kVA through 16 IEC C13 outlets
  • Accepts 100 V to 240 V AC single-phase input via IEC C20 inlet
  • Fits standard 19-inch racks in a 1U horizontal form factor
  • Delivers 16 A input current for high-density server deployments
  • Measures 1.70" high × 19.00" wide × 7.00" deep for compact installation

1U Horizontal PDU with 16 C13 Outlets

The Eaton PW103BA1U405 is a single-phase power distribution unit rated at 16 A and 3.33 kVA. It fits a standard 19-inch rack using only 1U of vertical space and provides sixteen IEC 60320 C13 sockets for connected equipment. The unit accepts a 100 V to 240 V AC supply through a single IEC 60320 C20 inlet.

Suited for dense rack rows needing many C13

This PDU serves administrators who must power multiple servers, switches or storage arrays from one 16 A branch circuit. It is not intended for installations that require metered or switched outlets, remote monitoring, or outlet-level control. Buyers needing higher current ratings, mixed receptacle types, or vertical mounting should evaluate alternative models.

Continuous 16 A load within rated thermal limits

The unit delivers its full 3.33 kVA rating as long as the supply remains within the 100 V to 240 V range and ambient conditions stay inside the manufacturer’s specified envelope. Internal bus bars and C13 contacts are sized for sustained 16 A operation without derating. No active cooling is present, so adequate rack airflow must be maintained to prevent heat build-up during prolonged maximum load.

Highlights

  • Distributes up to 3.33 kVA through 16 IEC C13 outlets
  • Accepts 100 V to 240 V AC single-phase input via IEC C20 inlet
  • Fits standard 19-inch racks in a 1U horizontal form factor
  • Delivers 16 A input current for high-density server deployments
  • Measures 1.70" high × 19.00" wide × 7.00" deep for compact installation

Specifications

BrandEaton
SeriesTPC214
ModelPW103BA1U405
TypeConsumer Electronics
Input Voltage100V AC to 240V AC Single-phase
FeaturesNumber of Output Connections: 16
Current: 16A Input Current
Output Receptacles: 16 x IEC 60320 C13
Form Factor: 1U
Form Factor: 1U Horizontal
Power Rating: 3.33 kVA
Power Rating: 3.33 kVA
Input Receptacles: IEC 60320 C20
Product Type: PDU
Product Name:TPC214 PW103BA1U405 16-Outlet 3.33kWatts PDU
Dimensions1.70" x 19.00" x 7.00"
Shipping weight3.63 kg
Package size508 × 305 × 51 mm

Questions about this item

What input connection does the PW103BA1U405 need from my UPS or wall supply?

It uses a single IEC 60320 C20 inlet rated for 16 A at 100 V to 240 V AC single-phase.

Can I still plug C14-equipped servers into the 16 C13 outlets on this 1U unit?

Yes, each of the 16 IEC 60320 C13 receptacles accepts a standard C14 plug from servers or network gear.

How do I confirm the PDU is delivering power once it is rack-mounted and wired?

Verify that connected devices power on normally and that total load stays within the 3.33 kVA rating.