We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton EMI102-10 0U Vertical 30 Outlets 2.88 kVA PDU

SKU CH-J0AN-2FE1M MPN EMI102-10

A 0U vertical PDU distributes 2.88 kVA through 30 NEMA 5-20R outlets from a single L5-30P input with metered monitoring

  • TypeOthers
  • Input Voltage120 V
  • FeaturesPower Rating:2.88 kVA Form Factor:Rack-mountable Product Typ
  • Weight15.10 lb
  • Metered input with ±1 % billing-grade accuracy for precise energy tracking
  • Advanced LCD pixel display shows current, voltage, power and energy locally
  • High-temperature rating of 60 °C suits containment and hot-aisle deployments
  • Hot-swap meter allows service without removing power from the rack
  • Daisy-chain networking lets four units share a single IP connection

0U Vertical 2.88 kVA PDU

The Eaton EMI102-10 is a rack-mountable power distribution unit built for vertical 0U installation in server cabinets. It delivers a 2.88 kVA power rating from a single NEMA L5-30P input plug. The unit provides thirty NEMA 5-20R output receptacles protected by two 20A circuit breakers. A hot-swap metering module allows service without powering down connected equipment.

IT Racks Needing High-Temp Input Metering

This PDU suits data centres and network closets where ambient temperatures reach 60 °C and billing-grade input monitoring is required. The LCD pixel display shows current, voltage, power and energy locally, while daisy-chain networking lets four units share one IP connection. Colour-coded outlet sections assist manual load balancing across the two breaker banks. Facilities without a NEMA L5-30P supply or that need outlet-level switching should consider alternative models.

Single NEMA L5-30P Input Connection

The product operates from one locking 120 V, 30 A input receptacle. No other input voltage, phase configuration or connector type is supported by this model. The thirty 5-20R outlets distribute that single source across two 20 A branch circuits. Verify that the site provides a compatible L5-30P feed before purchase.

Highlights

  • Metered input with ±1 % billing-grade accuracy for precise energy tracking
  • Advanced LCD pixel display shows current, voltage, power and energy locally
  • High-temperature rating of 60 °C suits containment and hot-aisle deployments
  • Hot-swap meter allows service without removing power from the rack
  • Daisy-chain networking lets four units share a single IP connection

Specifications

BrandEaton
ModelEMI102-10
TypeOthers
Input Voltage120 V
FeaturesPower Rating:2.88 kVA
Form Factor:Rack-mountable
Product Type:PDU
Power Rating:2.88 kVA
Form Factor:Rack-mountable
Input Receptacles:NEMA L5-30P
Product Name:ePDU 24-Outlets PDU
Output Receptacles:24 x NEMA 5-20R
Weight15.10 lb
Shipping weight6.83 kg
Package size1970 × 235 × 195 mm

Questions about this item

What does the NEMA L5-30P input plug limit the PDU to in practice?

The L5-30P plug connects to a 120 V, 30 A supply, capping usable power at 2.88 kVA.

What rack space and orientation does the 0U vertical chassis require?

It mounts in the 0U vertical channel of a standard rack and weighs 15.10 lb.

How is the hot-swap meter replaced without cutting power to the rack?

The meter module slides out while the PDU stays live, so connected equipment remains powered.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.