Eaton
Eaton EMAU07-10 PDU 16x C13 230 V 5.76 kVA 2U
A 2U rackmount PDU distributes 230 V AC power through sixteen C13 outlets from a single NEMA L6-30P input rated at 5.76 kVA
- TypeOthers
- Input Voltage230 V AC
- FeaturesOutput Receptacles:16 x IEC 320-C13 Product Name:ePDU 16-Out
- Weight17.34
- 16 IEC C13 outlets power multiple rack devices
- 76 kVA capacity supports high-density loads
- Network RJ-45 port enables remote monitoring
- Horizontal 2U form factor fits standard racks
- NEMA L6-30P input delivers 230 V at 24 A
16-Outlet 2U Rack PDU
The Eaton EMAU07-10 is a horizontal rackmount power distribution unit that supplies 16 IEC 60320 C13 outlets from a single NEMA L6-30P input. It is built for 230 V AC environments and fits a standard 19-inch rack using 2U of vertical space.
5.76 kVA at 24 A input
The unit delivers a 5.76 kVA rating with a 24 A input current limit, so the connected load must stay within that envelope. Network management is available through the RJ-45 port for remote monitoring and control.
Passive cooling in 2U height
No active fans are present; the PDU relies on passive airflow within the rack. The 3.4-inch height and 8.4-inch depth leave clearance for cable routing while adding 17.34 kg to the rack weight budget.
Highlights
- 16 IEC C13 outlets power multiple rack devices
- 76 kVA capacity supports high-density loads
- Network RJ-45 port enables remote monitoring
- Horizontal 2U form factor fits standard racks
- NEMA L6-30P input delivers 230 V at 24 A
Specifications
| Brand | Eaton |
|---|---|
| Model | EMAU07-10 |
| Type | Others |
| Input Voltage | 230 V AC |
| Features | Output Receptacles:16 x IEC 320-C13 Product Name:ePDU 16-Outlet PDU Form Factor:Horizontal Rackmount Input Receptacles:1 x NEMA L6-30P Power Rating:5.76 kVA Power Rating:5.76 kVA Form Factor:Horizontal Rackmount Product Type:PDU |
| Weight | 17.34 |
| Shipping weight | 7.80 kg |
| Package size | 580 × 483 × 170 mm |
Questions about this item
What does the 5.76 kVA rating mean for the devices I plug into this PDU?
It supports up to 5760 W total across all 16 C13 outlets at 230 V, so the combined load of connected servers or network gear must stay below that limit.
What does the NEMA L6-30P input plug cap in practice?
The 30 A plug feeds a 24 A input current, so the PDU can deliver its full 5.76 kVA rating from a compatible 230 V source.
Will this 2U unit fit my standard 19-inch rack?
Yes, it mounts horizontally in a 19-inch rack, occupying 2U of height with a depth of 8.4 inches and width of 3.4 inches.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.