We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton EMA333-10 Managed PDU 28-Outlets 8.64 kVA 120/230 V

SKU CH-M4Y0-K18H4 MPN EMA333-10

Rack-mountable managed PDU distributes 8.64 kVA across 28 outlets including 21 C13, six C19 and one NEMA 5-20R

  • TypeOthers
  • Input Voltage120 V AC 230 V AC
  • FeaturesPower Rating:8.64 kVA Form Factor:Rack-mountable Product Typ
  • Managed power monitoring for 28 outlets
  • 64 kVA capacity supports dense rack deployments
  • Dual 120 V and 230 V input compatibility
  • NEMA L21-30P input with mixed IEC C13 and C19 outputs
  • Rack-mountable form factor simplifies data-centre integration

Managed PDU with 28 outlets

The Eaton EMA333-10 is a rack-mountable managed power distribution unit delivering 8.64 kVA. It accepts 120 V AC or 230 V AC input through a NEMA L21-30P plug. The unit provides 28 output receptacles: one NEMA 5-20R, twenty-one IEC 60320 C13 and six IEC 60320 C19 sockets. Remote monitoring and outlet-level control are supported via the managed series platform.

Rack deployments needing dense monitored power

This PDU suits data-centre racks and server rooms that require single-phase or split-phase input with a high outlet count and per-outlet metering. It fits standard 19-inch cabinets and supports environments where capacity planning and remote reboot capability matter. Buyers who need only basic power distribution without network management should consider simpler strip models. Facilities lacking a NEMA L21-30P source or requiring three-phase input will need a different unit.

8.64 kVA rating and NEMA L21-30P input

The 8.64 kVA power rating determines the maximum connected load the PDU can support. The NEMA L21-30P input plug requires a matching 30 A branch circuit and receptacle on the upstream UPS or panel. Verify that your facility provides this exact connection before purchase.

Highlights

  • Managed power monitoring for 28 outlets
  • 64 kVA capacity supports dense rack deployments
  • Dual 120 V and 230 V input compatibility
  • NEMA L21-30P input with mixed IEC C13 and C19 outputs
  • Rack-mountable form factor simplifies data-centre integration

Specifications

BrandEaton
SeriesManaged
TypeOthers
Input Voltage120 V AC
230 V AC
FeaturesPower Rating:8.64 kVA
Form Factor:Rack-mountable
Product Type:PDU
Power Rating:8.64 kVA
Form Factor:Rack-mountable
Input Receptacles:NEMA L21-30P
Product Name:ePDU Managed 28-Outlets PDU
Output Receptacles:1 x NEMA 5-20R
21 x IEC 60320 C13
6 x IEC 60320 C19
Shipping weight9.21 kg
Package size2040 × 2040 × 236 mm

Questions about this item

What does the 8.64 kVA rating mean for equipment I can connect?

The 8.64 kVA rating indicates the maximum apparent power the PDU can distribute across its 28 outlets without overloading the NEMA L21-30P input.

What does the NEMA L21-30P input cap in practice?

The NEMA L21-30P input limits the PDU to a 30 A three-phase supply at 120/230 V AC, defining the total power available to all outlets.

What rack space does this 28-outlet PDU need to mount?

The rack-mountable form factor fits a standard 19-inch rack, using the included brackets for horizontal or vertical installation depending on the model length.