Eaton
Eaton EMA333-10 Managed PDU 28-Outlets 8.64 kVA 120/230 V
Rack-mountable managed PDU distributes 8.64 kVA across 28 outlets including 21 C13, six C19 and one NEMA 5-20R
- TypeOthers
- Input Voltage120 V AC 230 V AC
- FeaturesPower Rating:8.64 kVA Form Factor:Rack-mountable Product Typ
- Managed power monitoring for 28 outlets
- 64 kVA capacity supports dense rack deployments
- Dual 120 V and 230 V input compatibility
- NEMA L21-30P input with mixed IEC C13 and C19 outputs
- Rack-mountable form factor simplifies data-centre integration
Managed PDU with 28 outlets
The Eaton EMA333-10 is a rack-mountable managed power distribution unit delivering 8.64 kVA. It accepts 120 V AC or 230 V AC input through a NEMA L21-30P plug. The unit provides 28 output receptacles: one NEMA 5-20R, twenty-one IEC 60320 C13 and six IEC 60320 C19 sockets. Remote monitoring and outlet-level control are supported via the managed series platform.
Rack deployments needing dense monitored power
This PDU suits data-centre racks and server rooms that require single-phase or split-phase input with a high outlet count and per-outlet metering. It fits standard 19-inch cabinets and supports environments where capacity planning and remote reboot capability matter. Buyers who need only basic power distribution without network management should consider simpler strip models. Facilities lacking a NEMA L21-30P source or requiring three-phase input will need a different unit.
8.64 kVA rating and NEMA L21-30P input
The 8.64 kVA power rating determines the maximum connected load the PDU can support. The NEMA L21-30P input plug requires a matching 30 A branch circuit and receptacle on the upstream UPS or panel. Verify that your facility provides this exact connection before purchase.
Highlights
- Managed power monitoring for 28 outlets
- 64 kVA capacity supports dense rack deployments
- Dual 120 V and 230 V input compatibility
- NEMA L21-30P input with mixed IEC C13 and C19 outputs
- Rack-mountable form factor simplifies data-centre integration
Specifications
| Brand | Eaton |
|---|---|
| Series | Managed |
| Type | Others |
| Input Voltage | 120 V AC 230 V AC |
| Features | Power Rating:8.64 kVA Form Factor:Rack-mountable Product Type:PDU Power Rating:8.64 kVA Form Factor:Rack-mountable Input Receptacles:NEMA L21-30P Product Name:ePDU Managed 28-Outlets PDU Output Receptacles:1 x NEMA 5-20R 21 x IEC 60320 C13 6 x IEC 60320 C19 |
| Shipping weight | 9.21 kg |
| Package size | 2040 × 2040 × 236 mm |
Questions about this item
What does the 8.64 kVA rating mean for equipment I can connect?
The 8.64 kVA rating indicates the maximum apparent power the PDU can distribute across its 28 outlets without overloading the NEMA L21-30P input.
What does the NEMA L21-30P input cap in practice?
The NEMA L21-30P input limits the PDU to a 30 A three-phase supply at 120/230 V AC, defining the total power available to all outlets.
What rack space does this 28-outlet PDU need to mount?
The rack-mountable form factor fits a standard 19-inch rack, using the included brackets for horizontal or vertical installation depending on the model length.