Eaton
Eaton EMA113-10 Managed PDU 8-Outlet 1.92 kVA 120 V
Distributes 1.92 kVA at 120 V across eight NEMA 5-20R outlets from dual NEMA 5-20P and L5-20P inputs
- TypeOthers
- Input Voltage120 V AC
- FeaturesProduct Name:ePDU Managed 8-Outlet PDU Output Receptacles:8
- 8 outlets deliver reliable 120 V power to rack equipment
- 92 kVA capacity supports dense server deployments
- Managed series enables remote monitoring and control
- Vertical 0U form factor preserves rack space for IT gear
- Dual input cords NEMA 5-20P and L5-20P provide flexible site installation
Rack-mount power distribution for 120 V circuits
The Eaton EMA113-10 is a vertical managed PDU rated at 1.92 kVA on a 120 V AC supply. Eight NEMA 5-20R outlets deliver power to rack-mounted equipment from a single 20 A input. Network management allows remote outlet switching and monitoring.
Suited for 20 A single-phase racks
This unit fits cabinets that use NEMA 5-20P or NEMA L5-20P feeds and need eight 20 A receptacles. It is not for installations that require a different input connector, more than eight outlets, or a higher power rating.
1.92 kVA at 120 V AC
The 1.92 kVA rating defines the maximum load the PDU can support on a 120 V circuit. Exceeding this limit will trip the upstream breaker, so the connected equipment must stay within the rated capacity.
Highlights
- 8 outlets deliver reliable 120 V power to rack equipment
- 92 kVA capacity supports dense server deployments
- Managed series enables remote monitoring and control
- Vertical 0U form factor preserves rack space for IT gear
- Dual input cords NEMA 5-20P and L5-20P provide flexible site installation
Specifications
| Brand | Eaton |
|---|---|
| Series | Managed |
| Type | Others |
| Input Voltage | 120 V AC |
| Features | Product Name:ePDU Managed 8-Outlet PDU Output Receptacles:8 x NEMA 5-20R Form Factor:Vertical Input Receptacles:1 x NEMA 5-20P 1 x NEMA L5-20P Power Rating:1.92 kVA Product Type:PDU Form Factor:Vertical Power Rating:1.92 kVA |
| Shipping weight | 4.99 kg |
| Package size | 1194 × 254 × 203 mm |
Questions about this item
What plugs and cables come with the EMA113-10 and what must I supply?
The unit includes a vertical chassis with eight NEMA 5-20R outlets and two input plugs — one NEMA 5-20P and one NEMA L5-20P — so no input cable is required; you only need to provide the IEC or NEMA cords that connect your equipment to the 5-20R receptacles.
The specs show two different input plugs — 5-20P and L5-20P — which one should I use for a 120 V 20 A circuit?
Use the NEMA L5-20P locking plug for a dedicated 120 V 20 A branch circuit; the straight-blade 5-20P is an alternate connection for receptacles that do not accept a locking plug, but both are rated for the same 1.92 kVA capacity.
What does the 1.92 kVA rating mean for the actual load I can connect to the eight outlets?
At 120 V the 1.92 kVA rating equals a 16 A continuous current budget, so the combined draw of all devices plugged into the eight NEMA 5-20R outlets must stay at or below 16 A to avoid tripping the internal breaker.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.