Eaton
Eaton EHBPL2000R-PDU1U FlexPDU 1.92 kVA 125 V 6-Outlet PDU
A 1.92 kVA rackmount PDU distributes 125 V AC power through six outlets from two NEMA 5-20P inputs
- TypeOthers
- Input Voltage125 V AC
- Output Voltage125 V AC
- FeaturesPower Rating:1.92 kVA Form Factor:Horizontal Rackmount Produ
- Distributes 1.92 kVA from a single UPS
- Six NEMA 5-15/20R outlets for multiple devices
- Dual NEMA 5-20P inputs support flexible sourcing
- 1U horizontal rackmount fits standard cabinets
- Hot-swap bypass maintains uptime during battery service
Power distribution for single-UPS racks
The Eaton FlexPDU EHBPL2000R-PDU1U expands outlet count from one UPS with six NEMA 5-15/20R receptacles fed by dual NEMA 5-20P inputs. It mounts horizontally in a 1U rack space and accepts 125 V AC input and output at a 1.92 kVA rating. Network and server administrators who need more plug positions without adding a second UPS will use this unit.
Sustained 1.92 kVA delivery across six outlets
The 1.92 kVA rating applies to continuous load, not momentary peaks, so the PDU supports full rated current across all six receptacles as long as the upstream UPS and circuit can supply it. Dual 5-20P plugs draw from separate branch circuits when available, balancing thermal stress on internal bus bars and connectors during extended operation. No active cooling is present; heat dissipation relies on the rack airflow path.
Replaces basic power strips in managed environments
This unit replaces unmanaged power strips when rack density grows and outlet-level control or dual-circuit redundancy becomes necessary. The jump is worth it when equipment requires NEMA 5-20P input connections and the installer needs horizontal 1U mounting with a 2000 VA class UPS. It does not add metering, switching or remote monitoring capabilities.
Highlights
- Distributes 1.92 kVA from a single UPS
- Six NEMA 5-15/20R outlets for multiple devices
- Dual NEMA 5-20P inputs support flexible sourcing
- 1U horizontal rackmount fits standard cabinets
- Hot-swap bypass maintains uptime during battery service
Specifications
| Brand | Eaton |
|---|---|
| Series | FlexPDU |
| Model | EHBPL2000R-PDU1U |
| Type | Others |
| Input Voltage | 125 V AC |
| Output Voltage | 125 V AC |
| Features | Power Rating:1.92 kVA Form Factor:Horizontal Rackmount Product Type:PDU Power Rating:1.92 kVA Form Factor:Horizontal Rackmount Input Receptacles:2 x NEMA 5-20P Product Name:ePDU FlexPDU EHBPL2000R-PDU1U 6-Outlets PDU Output Receptacles:6 x NEMA 5-20R |
| Shipping weight | 2.36 kg |
| Package size | 475 × 190 × 70 mm |
Questions about this item
How much heat or noise does the 1.92 kVA FlexPDU produce when running continuously?
As a passive power distribution unit with no fans or active cooling, it generates no audible noise and negligible heat beyond what connected devices draw through its six outlets.
What input connection must my UPS or wall circuit provide for the dual NEMA 5-20P plugs?
The unit requires two 125 V AC circuits each terminated in a NEMA 5-20R receptacle rated for 20 A to feed its 1.92 kVA capacity.
Will my existing NEMA 5-15P equipment plug directly into the six output receptacles?
Yes — the six outlets accept both NEMA 5-15P and 5-20P plugs, so legacy 15 A gear works without adapters.