Eaton
Eaton 9PX2200GRT 2200 VA 2000 W 208V 10 Outlets 2U UPS
Double-conversion online UPS delivers 2200 VA and 2000 W at 208 V with ten IEC outlets in a 2U rack or tower form factor
- International Version208V
- Input Voltage RangeFull load: 176 - 276V, < 40% load: 100 - 276 V
- Input Frequency50/60 Hz
- Input ConnectionNEMA L6-20P
- VA Rating2200 VA
- Watts2000 Watts
- 2200 VA and 2000 W deliver reliable power for critical loads
- Double-conversion online topology provides clean, continuous output
- 10 outlets (8 C13 and 2 C19) support dense rack equipment
- 16 minutes runtime at half load keeps systems running during outages
- 2U form factor with included rails fits standard racks and towers
Double-Conversion Online UPS
The Eaton 9PX2200GRT is a double-conversion online uninterruptible power supply rated at 2200 VA and 2000 W with a 208 V output. It provides continuous power conditioning and battery backup for connected equipment. The unit fits a 2U rack space and includes a four-post rail kit and tower pedestals for flexible installation. Ten IEC outlets supply protected power to multiple devices.
IT Racks and Critical Loads
This UPS suits network closets, server rooms and edge sites that require clean sine-wave output and zero transfer time during outages. The NEMA L6-20P input and mixed C13 and C19 outlets match common rack power distributions. Buyers needing longer runtime at full load or a different input voltage should consider other models. Environments without 208 V service cannot use this unit.
6-Minute Runtime at Full Load
At 100 percent load the internal batteries deliver approximately 6 minutes of backup, rising to 16 minutes at half load. This figure determines whether the UPS can bridge the gap to generator start or allow a controlled shutdown. The battery is user-replaceable using the 9PXEBM72RT module. RS-232 and USB ports enable integration with Eaton Intelligent Power Manager for monitoring and automated shutdown scripts.
Highlights
- 2200 VA and 2000 W deliver reliable power for critical loads
- Double-conversion online topology provides clean, continuous output
- 10 outlets (8 C13 and 2 C19) support dense rack equipment
- 16 minutes runtime at half load keeps systems running during outages
- 2U form factor with included rails fits standard racks and towers
Specifications
| Brand | EATON |
|---|---|
| Model | 9PX2200GRT |
| International Version | 208V |
| Input Voltage Range | Full load: 176 - 276V, < 40% load: 100 - 276 V |
| Input Frequency | 50/60 Hz |
| Input Connection | NEMA L6-20P |
| VA Rating | 2200 VA |
| Watts | 2000 Watts |
| Output Voltage | 208V |
| Outlets | 10 |
| Outlet Type | 8 x IEC-320-C13 2 x IEC-320-C19 |
| Battery Run Time | At half load:16 minutes At full load: 6 minutes |
| Battery Replaceable | 9PXEBM72RT |
| Interface Port | RS-232, USB |
| Management Software | Eaton Intelligent Power Manager |
| Approvals | CE / cULus / NOM |
| Rackmountable | 2U |
| Dimensions | 3.40" x 17.30" x 23.80" |
| Weight | 60.40 lbs. |
| Shipping weight | 34.47 kg |
| Package size | 787 × 584 × 254 mm |
Questions about this item
What does the 2000 W rating mean for the equipment I can connect?
The 2000 W rating is the maximum real power the UPS can deliver continuously. Your connected load must not exceed 2000 W, even though the apparent power rating is 2200 VA.
What does the NEMA L6-20P input plug cap in practice?
The L6-20P plug requires a 20 A, 208 V branch circuit. The UPS will draw up to 20 A at full load, so the circuit breaker and wiring must support that rating.
How much rack space does the 2U chassis need and what mounting hardware is included?
The unit occupies 2U (3.40" height) in a standard 19" rack. A 4-post rail kit and tower pedestals are included for rack or tower installation.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



