We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton 9PX2200GRT 2200 VA 2000 W 208V 10 Outlets 2U UPS

SKU CH-PFWJ-Q6GSN MPN 9PX2200GRT

Double-conversion online UPS delivers 2200 VA and 2000 W at 208 V with ten IEC outlets in a 2U rack or tower form factor

  • International Version208V
  • Input Voltage RangeFull load: 176 - 276V, < 40% load: 100 - 276 V
  • Input Frequency50/60 Hz
  • Input ConnectionNEMA L6-20P
  • VA Rating2200 VA
  • Watts2000 Watts
  • 2200 VA and 2000 W deliver reliable power for critical loads
  • Double-conversion online topology provides clean, continuous output
  • 10 outlets (8 C13 and 2 C19) support dense rack equipment
  • 16 minutes runtime at half load keeps systems running during outages
  • 2U form factor with included rails fits standard racks and towers

Double-Conversion Online UPS

The Eaton 9PX2200GRT is a double-conversion online uninterruptible power supply rated at 2200 VA and 2000 W with a 208 V output. It provides continuous power conditioning and battery backup for connected equipment. The unit fits a 2U rack space and includes a four-post rail kit and tower pedestals for flexible installation. Ten IEC outlets supply protected power to multiple devices.

IT Racks and Critical Loads

This UPS suits network closets, server rooms and edge sites that require clean sine-wave output and zero transfer time during outages. The NEMA L6-20P input and mixed C13 and C19 outlets match common rack power distributions. Buyers needing longer runtime at full load or a different input voltage should consider other models. Environments without 208 V service cannot use this unit.

6-Minute Runtime at Full Load

At 100 percent load the internal batteries deliver approximately 6 minutes of backup, rising to 16 minutes at half load. This figure determines whether the UPS can bridge the gap to generator start or allow a controlled shutdown. The battery is user-replaceable using the 9PXEBM72RT module. RS-232 and USB ports enable integration with Eaton Intelligent Power Manager for monitoring and automated shutdown scripts.

Highlights

  • 2200 VA and 2000 W deliver reliable power for critical loads
  • Double-conversion online topology provides clean, continuous output
  • 10 outlets (8 C13 and 2 C19) support dense rack equipment
  • 16 minutes runtime at half load keeps systems running during outages
  • 2U form factor with included rails fits standard racks and towers

Specifications

BrandEATON
Model9PX2200GRT
International Version208V
Input Voltage RangeFull load: 176 - 276V, < 40% load: 100 - 276 V
Input Frequency50/60 Hz
Input ConnectionNEMA L6-20P
VA Rating2200 VA
Watts2000 Watts
Output Voltage208V
Outlets10
Outlet Type8 x IEC-320-C13
2 x IEC-320-C19
Battery Run TimeAt half load:16 minutes
At full load: 6 minutes
Battery Replaceable9PXEBM72RT
Interface PortRS-232, USB
Management SoftwareEaton Intelligent Power Manager
ApprovalsCE / cULus / NOM
Rackmountable2U
Dimensions3.40" x 17.30" x 23.80"
Weight60.40 lbs.
Shipping weight34.47 kg
Package size787 × 584 × 254 mm

Questions about this item

What does the 2000 W rating mean for the equipment I can connect?

The 2000 W rating is the maximum real power the UPS can deliver continuously. Your connected load must not exceed 2000 W, even though the apparent power rating is 2200 VA.

What does the NEMA L6-20P input plug cap in practice?

The L6-20P plug requires a 20 A, 208 V branch circuit. The UPS will draw up to 20 A at full load, so the circuit breaker and wiring must support that rating.

How much rack space does the 2U chassis need and what mounting hardware is included?

The unit occupies 2U (3.40" height) in a standard 19" rack. A 4-post rail kit and tower pedestals are included for rack or tower installation.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.