Eaton
Eaton 9PX1500RT 1500VA 1350W 120V UPS 8x 5-15R 2U Rack/Tower
Double-conversion UPS delivers 1500 VA / 1350 W with eight NEMA 5-15R outlets and 93 percent efficiency in a 2U rack/tower form factor
- International Version120V
- Input Voltage Range100 - 140V
- Input Frequency50/60 Hz
- Input ConnectionNEMA 5-15P
- VA Rating1500 VA
- Watts1350 Watts
- Online double-conversion topology provides pure sine-wave output with 0 ms transfer time
- 1350 W capacity powers critical loads through 8 NEMA 5-15R outlets
- Up to 93 % efficiency reduces energy cost and heat in rack or tower deployments
- Replaceable sealed lead-acid battery delivers 11 min runtime at half load and 4 min at full load
- Graphical LCD and RS-232 with management software enable local and remote monitoring
Double-Conversion 120V UPS for Critical Loads
The Eaton 9PX1500RT is a 1500 VA online double-conversion UPS delivering 1350 W of conditioned 120 V power. It accepts a wide 100–140 V input range at 50 or 60 Hz and connects via a NEMA 5-15P plug. Eight NEMA 5-15R outlets supply protected equipment in a 2U rack or tower form factor.
Zero-Transfer Topology and Efficiency Limits
Double-conversion operation provides 0 ns transfer time and continuous power conditioning for sensitive electronics. The unit reaches up to 93 percent efficiency in this mode. Management relies on an RS-232 interface and included software; a cybersecure network card slot is available for optional remote monitoring.
Runtime Scaling from Full to Light Loads
Battery runtime is approximately 4 minutes at 1350 W, 11 minutes at 675 W and 23 minutes at 337.5 W. Sealed lead-acid batteries are user-replaceable to extend service life. The UPS is not suited for loads exceeding 1350 W or for applications requiring extended runtime without additional battery modules.
Highlights
- Online double-conversion topology provides pure sine-wave output with 0 ms transfer time
- 1350 W capacity powers critical loads through 8 NEMA 5-15R outlets
- Up to 93 % efficiency reduces energy cost and heat in rack or tower deployments
- Replaceable sealed lead-acid battery delivers 11 min runtime at half load and 4 min at full load
- Graphical LCD and RS-232 with management software enable local and remote monitoring
Specifications
| Brand | Eaton |
|---|---|
| Series | 9PX |
| Model | 9PX1500RT |
| International Version | 120V |
| Input Voltage Range | 100 - 140V |
| Input Frequency | 50/60 Hz |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500 VA |
| Watts | 1350 Watts |
| Output Voltage | 120V |
| Outlets | 8 |
| Outlet Type | 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | At 100% load (1350W): Around 4 minutes At 50% load (675W): Around 11 minutes At 25% load (337.5W): Around 23 minutes |
| Battery Replaceable | YES |
| Alarms | YES |
| Interface Port | RS-232 |
| Management Software | YES |
| Rackmountable | Yes |
| Weight | 45 |
| Package Contents | 9PX1500RT 1500 VA UPS 4-post rail kit Safety manual User manual Tower pedestals RS-232 serial cable USB cable Intelligent Power Software Suite CD |
| VA | 1500 VA |
| Shipping weight | 25.40 kg |
| Package size | 584 × 559 × 254 mm |
Questions about this item
How do I pick the right VA or wattage rating for my load?
This model delivers 1500 VA and 1350 W. Total the watts of every device you will plug in; if the sum stays below 1350 W the UPS can support it.
What does the 1350 W rating mean once the unit is installed?
It is the maximum real power the inverter can supply continuously. At that full 1350 W load the battery lasts around 4 minutes; at 675 W it lasts around 11 minutes; at 337.5 W it lasts around 23 minutes.
What management interface does the UPS provide and what does it limit?
An RS-232 port is built in for monitoring and shutdown software. The serial link caps cable length and speed, so the management station must be close to the rack.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.