Eaton
Eaton 5P1500R-L 1440 VA 1100W Lithium-ion UPS
Rack-mountable lithium-ion UPS delivers 1440 VA and 1100 W true sine-wave power with four minutes runtime at full load
- International Version120V default (100/110/120/125V)
- Input Voltage Range89-151 Vac (adjustable to 70-153 Vac)
- Input Frequency50-60 Hz
- Input Connection5-15P
- VA Rating1440 VA
- Watts1100W
VA 1440 VA
- 1440 VA
- 1550 VA
Struck-through versions exist but are not stocked here.
- Lithium-ion battery reduces weight to 35 lbs for easier rack installation
- True sine wave output protects sensitive equipment with clean 120V power
- 1440 VA and 1100W capacity supports critical loads during outages
- 1U rackmount design fits standard cabinets while saving vertical space
- USB and RS-232 ports enable direct monitoring with included management software
Lithium-ion UPS for Rack Deployments
The Eaton 5P1500R-L is a 1440 VA, 1100 W lithium-ion uninterruptible power supply designed for 1U rack or wall mounting. It delivers true sine wave output at 120 V default to protect servers, network gear and storage arrays. Five NEMA 5-15R outlets connect critical loads while a single 5-15P plug draws from 100–125 V utility sources.
Thermal and Acoustic Profile
Lithium-ion chemistry runs cooler than traditional lead-acid designs, reducing heat output inside the rack. The 1U form factor allows dense stacking without blocking airflow to adjacent equipment. Input voltage tolerance spans 89–151 Vac, adjustable to 70–153 Vac, so the unit stays online through sags and swells without transferring to battery and cycling the cells.
Integration and Expandability
RS-232 over RJ45 and USB HID ports ship standard for direct server or network management card connectivity. Eaton Intelligent Power Manager software is included for graceful shutdown and monitoring across the environment. The package provides a four-post rail kit and wall-mount brackets, while the replaceable battery cartridge extends service life without replacing the entire chassis.
Highlights
- Lithium-ion battery reduces weight to 35 lbs for easier rack installation
- True sine wave output protects sensitive equipment with clean 120V power
- 1440 VA and 1100W capacity supports critical loads during outages
- 1U rackmount design fits standard cabinets while saving vertical space
- USB and RS-232 ports enable direct monitoring with included management software
Specifications
| Brand | EATON |
|---|---|
| Model | 5P1500R-L |
| International Version | 120V default (100/110/120/125V) |
| Input Voltage Range | 89-151 Vac (adjustable to 70-153 Vac) |
| Input Frequency | 50-60 Hz |
| Input Connection | 5-15P |
| VA Rating | 1440 VA |
| Watts | 1100W |
| Output Voltage | 120V default (100/120/125V) |
| Outlets | 5 |
| Outlet Type | 5-15R |
| Battery Run Time | 4 min (1100W) |
| Battery Replaceable | Yes |
| Interface Port | RS-232 (RJ45) ports; USB port as standard (HID) |
| Management Software | Eaton Intelligent Power Manager (included) |
| Rackmountable | 1U |
| Dimensions | 1.70" x 17.40" x 21.80" |
| Weight | 35 lbs. |
| Package Contents | UPS Quick start guide Safety instructions USB communciation cable RS-232 serial communication cable 4-post rail and wallmount kit |
| Shipping weight | 16.33 kg |
| Package size | 743 × 591 × 165 mm |
Questions about this item
How do I install the 1U rackmount kit and which step is commonly missed?
Mount the 4-post rails to the rack first, then slide the 1.70" high chassis in and secure the front brackets; the step often missed is tightening the rear rail screws after the unit is seated.
When will the lithium-ion battery need replacement and is it user-replaceable?
The lithium-ion battery is user-replaceable and typically lasts 8-10 years; replace when runtime drops below the 4 min at 1100W spec or the management software reports end-of-life.
What is the first limit reached during a sustained 1100W outage?
Battery runtime is the first limit at 4 minutes when loaded to 1100W; after that the UPS shuts down until utility power returns.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.