We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

DBX

DBX ZC-2 Zone Controller for Server Racks 1000 ft

SKU CH-G2PF-2B388

Programmable volume and mute zone controller wired with CAT5 cable up to 1000 ft

  • Programmable volume and mute control for DriveRack and ZonePRO systems
  • Analog DC voltage logic enables source selection and scene control
  • CAT5 cable with RJ-45 connectors simplifies contractor installation
  • Supports fire safety muting for critical applications
  • Wired operation up to 1000 ft extends zone coverage

DBX ZC-2 Zone Controller for Server Racks

The DBX ZC-2 is a programmable volume and mute zone controller designed for integration with DriveRack and ZonePRO systems. It provides logic control for source selection, volume adjustment, muting, program or scene selection, and fire safety muting. This unit suits contractors and installers managing multi-zone audio in commercial or installed sound environments. It is not for buyers needing networked digital control, wireless operation, or integrated amplification.

Wired CAT5 Connection up to 1000 ft

The controller connects using standard CAT5 cable with RJ-45 connectors, transmitting analog DC voltage for logic signals over distances up to 1000 ft. This single specification determines whether the cabling infrastructure matches the installation site. If the required run exceeds this length or the project demands fibre or digital audio transport, this controller will not meet the requirement.

Simple RJ-45 Wiring with Analog Voltage Logic

Installation uses readily available CAT5 cable and universally accepted RJ-45 connectors, simplifying the wiring process for contractors. The system relies on analog DC voltage for control logic, so installers must verify that cable runs stay within the 1000 ft limit and that the connected DriveRack or ZonePRO unit supplies the correct control voltages. Miswired RJ-45 pinouts or excessive cable length are the most common causes of unreliable zone operation.

Highlights

  • Programmable volume and mute control for DriveRack and ZonePRO systems
  • Analog DC voltage logic enables source selection and scene control
  • CAT5 cable with RJ-45 connectors simplifies contractor installation
  • Supports fire safety muting for critical applications
  • Wired operation up to 1000 ft extends zone coverage

Specifications

No published specifications for this item yet.

Questions about this item

What does the 1000 ft range mean when the zone controller is installed in a server rack?

The 1000 ft figure is the maximum cable run between this controller and the DriveRack or ZonePRO processor using CAT5 cable with RJ-45 connectors.

Which interface standard does the ZC-2 use and what does it limit in practice?

It uses analog DC voltage over CAT5 cable with RJ-45 connectors, limiting control signals to logic functions such as volume, mute, source selection and fire safety muting.

What physical mounting does the ZC-2 need to fit in a server rack?

The controller is designed for standard server rack or cabinet installation as part of the Server Racks and Cabinets category.

New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.