We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PR750RT2UC UPS 750VA/750W 120V 2U Rack Tower 8 Outlets

SKU CH-M1W5-NM779 MPN PR750RT2UC

Line-interactive UPS with sine-wave output, 750 VA/750 W, 8 NEMA 5-15R outlets, and 19 minutes runtime at half load

  • Input Voltage Range75 - 149V
  • Input Frequency47 - 63 Hz
  • Input ConnectionNEMA 5-15P
  • VA Rating750 VA
  • Watts750 Watts
  • Output Voltage100/110/120/125 VAC +/- 5%
  • Sine wave output matches utility power for sensitive electronics
  • 750 VA and 750 W capacity supports critical loads
  • 8 NEMA 5-15R outlets provide surge and battery backup
  • 19 minutes runtime at half load keeps systems running
  • 2430 joules surge rating protects connected equipment

Smart App Sinewave 750 VA UPS

The CyberPower PR750RT2UC is a line-interactive uninterruptible power supply rated at 750 VA and 750 W with pure sine wave output. It suits network gear, servers or workstations that require clean power during outages or brownouts. The 2U rack-tower chassis fits standard racks or sits on a shelf, and the 10 ft input cord uses a NEMA 5-15P plug for ordinary 120 V circuits. Buyers who need extended runtime beyond the internal battery or higher VA capacity should look elsewhere.

Line-interactive topology with AVR

Automatic Voltage Regulation corrects sags and swells from 75 V to 149 V without draining the battery, keeping the sealed lead-acid cells in reserve for true blackouts. At full 750 W load the unit runs for 7.5 minutes; at half load it delivers 19 minutes. Recharge from empty to 90 percent takes 3 hours. Audible alarms signal battery mode, low battery, overload, overcharge and overheat conditions. The 2430 J surge rating handles transient spikes on the 120 V line.

Replaceable battery pack and management ports

The RB1250X4 battery cartridge is user-replaceable through the toolless front panel, and color-coded rear outlets simplify cable routing. Eight NEMA 5-15R receptacles provide both battery backup and surge protection for connected devices. A serial port and a dry-contact interface enable integration with monitoring software or building management systems. The LCD readout shows load, voltage and battery status at a glance. Installers needing hardwired input or three-phase distribution cannot use this model.

Highlights

  • Sine wave output matches utility power for sensitive electronics
  • 750 VA and 750 W capacity supports critical loads
  • 8 NEMA 5-15R outlets provide surge and battery backup
  • 19 minutes runtime at half load keeps systems running
  • 2430 joules surge rating protects connected equipment

Specifications

BrandCyberPower
SeriesSmart App Sinewave
ModelPR750RT2UC
Input Voltage Range75 - 149V
Input Frequency47 - 63 Hz
Input ConnectionNEMA 5-15P
VA Rating750 VA
Watts750 Watts
Output Voltage100/110/120/125 VAC +/- 5%
Output Frequency50/60 Hz +/- 1%
Outlets8
Outlet Type8 x NEMA 5-15R
Battery TypeSealed Lead Acid
Battery Run TimeRuntime at Full Load: 7.5 min
Runtime at Half Load: 19 min
Battery Recharge Time3 Hours (0% to 90% charged)
Battery ReplaceableRB1250X4
AlarmsBattery Mode
Low Battery
Overload
Overcharge
Overheat
Interface Port1 Serial, 1 Dry Contact
RackmountableYes
Surge Energy Rating2430 Joules
ProtectionInternal Circuitry Limiting
Circuit Breaker Protected
Dimensions17.1" x 3.4" x 16.2"
Weight43.2 lbs.
Shipping weight23.77 kg
Package size559 × 527 × 267 mm

Questions about this item

How do I install the PR750RT2UC in a 2U rack and which step is often missed?

Mount the unit using the included rack ears, then connect the NEMA 5-15P plug to a 120 V circuit and link equipment to the eight NEMA 5-15R outlets; the step often missed is installing the PowerPanel Business software and connecting the serial or dry-contact cable so the UPS can signal the OS before battery runs out.

What maintenance will the PR750RT2UC need and which part is user-replaceable?

The sealed lead-acid battery pack is user-replaceable; the specified replacement module is RB1250X4, and typical service life is three to five years before runtime drops below the rated 19 minutes at half load or 7.5 minutes at full load.

What limit appears first when the PR750RT2UC runs at full 750 W load for an extended period?

Battery runtime ends after 7.5 minutes at full load, after which the UPS shuts down; the 2430-joule surge rating and 75–149 V input window do not limit operation before the battery is depleted.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.