CyberPower
CyberPower PDU44002 Switched 1U PDU 100-120V 20A 10ft
Switched 1U rackmount PDU distributes 100-120 VAC at up to 16 A derated with a 10 ft cord
- TypeSwitched
- Rack Size1U
- StyleRackmount
- Input Frequency50/60 Hz
- Maximum Input Current20A
- Regulatory Derated Input Current16A
- Switched control enables remote outlet management per socket
- 1U rackmount design installs in standard server racks
- 20 A maximum input current supports high-density loads
- 10 ft input cord provides flexible rack placement
- 100–120 VAC output voltage matches North American power
Switched 1U rack PDU
The CyberPower PDU44002 is a switched power distribution unit designed for 1U rackmount installation. It accepts 100 to 120 VAC input at 50 or 60 Hz with a 20 A maximum current and a 16 A regulatory derated limit. A 10 ft cord connects the unit to the supply.
Suited for 120 V switched outlet control
This unit suits administrators who need remote on/off control of individual outlets in a 120 V rack environment. It is not for buyers who need a higher input voltage range or a derated current above 16 A.
20 A maximum input current rating
The 20 A maximum input current and 16 A regulatory derated current define the total load the PDU can support. Verify that your equipment stays within these limits before deployment.
Highlights
- Switched control enables remote outlet management per socket
- 1U rackmount design installs in standard server racks
- 20 A maximum input current supports high-density loads
- 10 ft input cord provides flexible rack placement
- 100–120 VAC output voltage matches North American power
Specifications
| Brand | CyberPower |
|---|---|
| Model | PDU44002 |
| Type | Switched |
| Rack Size | 1U |
| Style | Rackmount |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 20A |
| Regulatory Derated Input Current | 16A |
| Cord Length | 10 ft |
| Output Voltage | 100 - 120 VAC |
| Dimensions | 1.75" x 17.05" x 8.45" |
| Weight | 11.30 lbs. |
| Shipping weight | 7.03 kg |
| Package size | 550 × 398 × 124 mm |
Questions about this item
How much heat does the CyberPower PDU44002 generate when running continuously at the 16A derated load?
The unit draws up to 16A at 100-120 VAC, so sustained operation produces heat proportional to the connected equipment's draw; the metal chassis and 1U ventilation slots dissipate it passively without internal fans.
What rack hardware and input circuit are required to install the PDU44002?
It fits a standard 1U rack space and needs a 20A branch circuit with a NEMA L5-20P receptacle to match the 10 ft input cord and 20A maximum rating.
Will the switched outlets on this PDU44002 control legacy servers that only accept a hard power cycle?
Yes, each outlet can be toggled remotely, cutting and restoring AC power to older gear exactly like a manual power switch.