We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU33110 3-Phase 200-240V 60A Monitored PDU 18 Outlets 10ft IEC-309 60A Blue Vertical 0U LCD

SKU CH-TXKY-KQKW7 MPN PDU33110

Three-phase monitored PDU delivering 200-240 V at 48 A through 18 IEC outlets with a 10 ft IEC-309 cord

  • 3-phase 200-240 V power feeds high-density racks
  • 60 A input derated to 48 A protects circuits under load
  • 18 mixed IEC-320 C13 and C19 outlets support varied gear
  • 0U vertical mounting preserves rack space for servers
  • LCD plus email SMS SNMP alerts enable remote monitoring

Three-phase monitored PDU

The CyberPower PDU33110 is a three-phase monitored power distribution unit rated for 200-240 VAC at 60 A, derated to 48 A. It suits data-centre racks and server rooms that need per-outlet visibility and remote alarming via email, SMS or SNMP traps.

Eighteen mixed IEC outlets

The unit provides six IEC-320 C13 and twelve IEC-320 C19 sockets fed by a 10 ft cord ending in an IEC-309 60 A blue 3P+E plug. Vertical 0U mounting leaves full rack depth for equipment while keeping cables organised along the cabinet side.

Local LCD metering

A built-in LCD shows real-time voltage, current and power data for each phase without external software. Monitoring is passive, adding no fan noise or extra heat, and the 50/60 Hz input range matches global three-phase supplies.

Highlights

  • 3-phase 200-240 V power feeds high-density racks
  • 60 A input derated to 48 A protects circuits under load
  • 18 mixed IEC-320 C13 and C19 outlets support varied gear
  • 0U vertical mounting preserves rack space for servers
  • LCD plus email SMS SNMP alerts enable remote monitoring

Specifications

No published specifications for this item yet.

Questions about this item

What current does the IEC-309 60A Blue (3P+E) input actually deliver to the outlets?

The 60 A three-phase inlet is derated to 48 A, so the 18 outlets share a maximum of 48 A at 200-240 V.

How much vertical rack space does the 0U form factor of the PDU33110 consume?

Zero rack units; the unit mounts along the side of a standard 19-inch cabinet without using any front-facing U spaces.

Does the PDU33110 ship with brackets for tool-less vertical mounting?

The unit includes toolless mounting buttons that snap into square-hole or round-hole rails; no separate brackets are required.