We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
CyberPower
Distributes 120 V power to 14 NEMA 5-15R outlets from a single NEMA 5-15P input with front LCD amp metering for real-time load monitoring
The CyberPower PDU15M2F12R distributes 120V 15A power to fourteen NEMA 5-15R receptacles from a single NEMA 5-15P input. A front LCD shows real-time current draw in amps for immediate load awareness. The unit fits standard rack environments with horizontal or vertical mounting options and a 15-foot cord. Industrial-grade metal housing and ETL/RoHS certification support demanding datacentre deployments.
Total connected equipment must not exceed 15 amps at 120 volts, a hard ceiling set by the input plug and overload protection. The unfiltered pass-through delivers raw utility power without conditioning or surge suppression. Monitoring is read-only; the LCD reports load but cannot shed outlets or alert remotely. Buyers needing filtered power, remote switching or higher amperage service will need a different class of unit.
Fourteen NEMA 5-15R ports give dense outlet count for multi-device racks, yet the 15-amp budget is shared across all of them. Typical server gear drawing one to two amps each fits several units before headroom vanishes. High-draw appliances such as heaters or large UPS chargers will saturate the circuit with only one or two loads. Plan the aggregate load before populating every receptacle.
| Brand | CyberPower |
|---|---|
| Model | MPN-PDU15M2F12R |
| Type | Power Distribution Units |
This unit provides exactly 14 NEMA 5-15R receptacles. If your rack needs more or fewer outlets, you would need a different model.
The 15 A rating is the maximum total current the PDU can supply to all 14 outlets combined. Exceeding it will trip the built-in overload protection.
The NEMA 5-15P plug connects to a standard 120 V 15 A wall circuit, so the PDU cannot draw more than that circuit allows.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?