We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU15M2F12R Metered PDU 14 Outlets 120V 15A

SKU CH-ZB62-53Z9T MPN PDU15M2F12R

Distributes 120 V power to 14 NEMA 5-15R outlets from a single NEMA 5-15P input with front LCD amp metering for real-time load monitoring

  • TypePower Distribution Units
  • Real-time load monitoring via front LCD amp display
  • 14 NEMA 5-15R outlets from a single NEMA 5-15P input
  • Overload protection safeguards connected equipment
  • Rugged metal housing built for datacenter environments
  • Horizontal or vertical mounting with cord retention tray

Metered 14-Outlet PDU

The CyberPower PDU15M2F12R distributes 120V 15A power to fourteen NEMA 5-15R receptacles from a single NEMA 5-15P input. A front LCD shows real-time current draw in amps for immediate load awareness. The unit fits standard rack environments with horizontal or vertical mounting options and a 15-foot cord. Industrial-grade metal housing and ETL/RoHS certification support demanding datacentre deployments.

15A Circuit Limit

Total connected equipment must not exceed 15 amps at 120 volts, a hard ceiling set by the input plug and overload protection. The unfiltered pass-through delivers raw utility power without conditioning or surge suppression. Monitoring is read-only; the LCD reports load but cannot shed outlets or alert remotely. Buyers needing filtered power, remote switching or higher amperage service will need a different class of unit.

Fourteen Outlets at 15A

Fourteen NEMA 5-15R ports give dense outlet count for multi-device racks, yet the 15-amp budget is shared across all of them. Typical server gear drawing one to two amps each fits several units before headroom vanishes. High-draw appliances such as heaters or large UPS chargers will saturate the circuit with only one or two loads. Plan the aggregate load before populating every receptacle.

Highlights

  • Real-time load monitoring via front LCD amp display
  • 14 NEMA 5-15R outlets from a single NEMA 5-15P input
  • Overload protection safeguards connected equipment
  • Rugged metal housing built for datacenter environments
  • Horizontal or vertical mounting with cord retention tray

Specifications

BrandCyberPower
ModelMPN-PDU15M2F12R
TypePower Distribution Units

Questions about this item

Should I choose the 14-outlet version or a different capacity?

This unit provides exactly 14 NEMA 5-15R receptacles. If your rack needs more or fewer outlets, you would need a different model.

What does the 15 A rating mean once the PDU is installed?

The 15 A rating is the maximum total current the PDU can supply to all 14 outlets combined. Exceeding it will trip the built-in overload protection.

How does the NEMA 5-15P input limit what I can plug in?

The NEMA 5-15P plug connects to a standard 120 V 15 A wall circuit, so the PDU cannot draw more than that circuit allows.