CyberPower
CyberPower PDU15M2F10R 12-outlet metered PDU 15A 120V
A 1U rack-mount metered PDU distributes 120V 15A power to 12 NEMA 5-15R outlets with a front LCD amp display and 15-foot cord
- Real-time load monitoring via front LCD amp display
- 12 NEMA 5-15R outlets (2 front, 10 rear) from single 5-15P input
- 15 A, 120 V metered power distribution for dense racks
- Rugged metal housing with horizontal or vertical mounting options
- 15-foot cord with retention tray, ETL/RoHS certified
Rack-mount metered PDU with 12 NEMA 5-15R outlets
The CyberPower PDU15M2F10R distributes 120V 15A power to twelve receptacles from a single NEMA 5-15P input. A front LCD shows real-time current draw in amps for load monitoring. The 1U metal housing mounts horizontally or vertically and includes a 15-foot cord with a retention tray. It is ETL and RoHS certified for datacenter use.
Suited for racks needing local amp monitoring
This unit fits administrators who want visible load data without network connectivity. The unfiltered pass-through delivers raw utility power to connected gear. Buyers who need switched outlet control, environmental sensors or remote access via SNMP should consider a different class of power distribution unit. The fixed 15A rating also limits use on higher-capacity branch circuits.
Single 15A NEMA 5-15P input plug
The cord terminates in a standard 15A 120V plug, so the PDU must connect to a matching 15A branch circuit. Installations wired for 20A receptacles or other voltages will require a different power distribution unit. Verify your facility outlet type before ordering.
Highlights
- Real-time load monitoring via front LCD amp display
- 12 NEMA 5-15R outlets (2 front, 10 rear) from single 5-15P input
- 15 A, 120 V metered power distribution for dense racks
- Rugged metal housing with horizontal or vertical mounting options
- 15-foot cord with retention tray, ETL/RoHS certified
Specifications
| Brand | CyberPower |
|---|---|
| Model | PDU15M2F10R |
Questions about this item
What rack space does this 1U PDU need for horizontal or vertical mounting?
The unit occupies a single 1U rack space and includes hardware for both horizontal and vertical mounting orientations.
How do you secure the 15-foot input cord so it cannot pull loose from the NEMA 5-15P plug?
Route the cord through the supplied retention tray and tighten the tray screws before connecting the plug to the branch circuit.
What ongoing check does the front LCD let you perform on the 12 NEMA 5-15R outlets?
The LCD shows real-time total current draw in amps so you can verify the 15 A load limit is never exceeded.