We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower PDU15B8R 1U 8-Outlet PDU 120V 15A

SKU CH-6EVC-TFJ8C MPN PDU15B8R

Distributes 120V power to eight NEMA 5-15R outlets from a single 15A input with a 15-foot cord, in a 1U metal chassis that mounts horizontally or vertically

  • TypeBasic
  • Rack Size1U
  • StyleRackmount, Vertical Rackmount, Under-Counter
  • CertificationsUL1363 certified by ETL (USA), CSA C22.2 (Canada)
  • ROHSYes
  • Input Voltage120V
  • Delivers 120 V power to eight NEMA 5-15R outlets from one 5-15P plug
  • 1 U rack-mount design fits standard cabinets horizontally or vertically
  • 15 ft cord reaches distant power sources without extra leads
  • UL 1363 and CSA C22.2 certified for North American safety compliance
  • Rugged metal housing withstands 32 °F to 95 °F operating temperatures

Rackmount PDU with eight NEMA 5-15R outlets

The CyberPower PDU15B8R is a 1U basic power distribution unit that delivers 120V 15A output from a single NEMA 5-15P input. It suits server racks, network cabinets and under-counter installations where multiple devices need reliable unfiltered pass-through power. The 15-foot cord provides flexible placement in data centres or office environments.

Continuous 15A load handling

The unit supports a maximum input current of 15A with integrated overload protection rated at the same level. It maintains steady output across the full operating temperature range of 0 °C to 35 °C and up to 95% non-condensing humidity. Metal housing and ETL certification to UL 1363 and CSA C22.2 ensure consistent performance under sustained electrical demand.

Passive cooling with zero fan noise

No moving parts mean silent operation and no additional power draw beyond the connected loads. The rugged metal chassis dissipates heat naturally within the specified elevation limit of 3,000 m. Storage tolerances extend from -15 °C to 45 °C and 15,000 m, so the PDU remains ready for deployment after extended periods in harsh conditions.

Highlights

  • Delivers 120 V power to eight NEMA 5-15R outlets from one 5-15P plug
  • 1 U rack-mount design fits standard cabinets horizontally or vertically
  • 15 ft cord reaches distant power sources without extra leads
  • UL 1363 and CSA C22.2 certified for North American safety compliance
  • Rugged metal housing withstands 32 °F to 95 °F operating temperatures

Specifications

BrandCyberPower
ModelPDU15B8R
TypeBasic
Rack Size1U
StyleRackmount, Vertical Rackmount, Under-Counter
CertificationsUL1363 certified by ETL (USA), CSA C22.2 (Canada)
ROHSYes
Input Voltage120V
Input Frequency50/60 Hz
Maximum Input Current15A
Input Connector(s)NEMA 5-15P
Cord Length15 ft.
Output Voltage120V
Output Connector(s)NEMA 5-15R
Overload Protection15A
Operating Environment32 °F to 95 °F / 0 °C to 35 °C
Operating Relative Humidity0% - 95% non-condensing
Operating Elevation10,000 ft / 3,000 m
Storage Temperature5 °F to 113°F / -15°C to 45 °C
Storage Elevation50,000 ft / 15,000 m
FeaturesCyberPower Basic PDU15B8R 8-Outlets PDU - 8 x NEMA 5-15R - 1URack-mountable
Dimensions17.5" x 1.75" x 1.5"
Weight3.5 lbs
Shipping weight2.26 kg
Package size505 × 155 × 71 mm

Questions about this item

Does the 15 A basic PDU generate noticeable heat or noise when running continuously?

The unit has no fans or active cooling, so it runs silently and adds only minimal heat from the 15 A pass-through current.

What plug and receptacle types must already exist in the rack for the PDU15B8R to connect?

You need a single NEMA 5-15P inlet feeding the 15 ft cord and eight NEMA 5-15R outlets on the strip.

Will the 120 V PDU work alongside older 120 V equipment rated below 15 A?

Yes, it delivers standard 120 V to each 5-15R receptacle, so legacy gear drawing up to 15 A total operates normally.