Innovation First, Inc. 1UCMA-137 1U Cable Management Arm 19" 28.5"-33" computer accessory
- Product Type:Cable…
- Panel Width:19" Rac…
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
CyberPower
Rack-mount UPS delivers 1500 VA and 900 W with eight NEMA 5-15R outlets, 18 minutes runtime at half load, and 1840 joules surge protection
The CyberPower OR1500LCDRT2U is a 1500 VA 900 W battery backup designed for 2U rack installation. It protects connected equipment from outages and voltage fluctuation within a 90 to 140 V input window. Eight NEMA 5-15R outlets distribute conditioned 120 VAC power to critical devices. The sealed lead-acid battery is user-replaceable for extended service life.
The unit operates at 50 or 60 Hz with a tolerance of 3 Hz on input and 1 percent on output. Audible alarms signal on-battery, low-battery, overload, missing-battery and fault conditions so operators can react without checking software. Surge protection is rated at 1840 joules to absorb transient spikes. The 3.5 inch rack height fits standard enclosures while the 48.4 lb weight requires secure mounting.
PowerPanel management software enables remote monitoring and graceful shutdown of attached servers over the network. The replaceable battery cartridge can be swapped without powering down the load, reducing maintenance downtime. An eight-hour recharge cycle restores full runtime after a discharge event. Buyers needing longer runtime at full load or higher VA capacity should consider additional battery packs or a larger unit.
| Brand | CyberPower |
|---|---|
| Series | Smart App LCD UPS Series |
| Model | OR1500LCDRT2U |
| Input Voltage Range | 90 - 140V |
| Input Frequency | 50/60 Hz +/-3 Hz |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500 VA |
| Watts | 900 Watts |
| Output Voltage | 120 VAC +/- 10% |
| Output Frequency | 50/60 Hz +/- 1% |
| Outlets | 8 |
| Outlet Type | NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | 18 mins at Half Load 6 mins at Full Load |
| Battery Recharge Time | 8 hours |
| Battery Replaceable | Yes |
| Alarms | On Battery Low Battery Overload Battery Missing Fault |
| Surge Energy Rating | 1840 Joules |
| Dimensions | 17.25" × 3.5" × 15.75" |
| Weight | 48.4 lbs. |
| Shipping weight | 24.90 kg |
| Package size | 546 × 521 × 292 mm |
Mount the unit using the included rack ears so it occupies 3.5 inches of vertical space; the step often missed is plugging the NEMA 5-15P input into a properly grounded 120 V circuit before turning the UPS on.
The battery is user-replaceable and typically lasts three to five years; plan to swap it when runtime drops below the rated 18 minutes at half load or 6 minutes at full load.
Battery runtime ends after approximately 6 minutes at full load, which is the first hard limit during sustained use.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?