We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower OL1K5RM UPS 1500VA 1200W 2U Rackmount Online Double Conversion 100-125V 8x NEMA 5-15R

SKU CH-VF7F-WY478 MPN OL1K5RM

Rackmount online UPS delivering 1500 VA and 1200 W with double-conversion topology, zero transfer time, pure sine-wave output and eight NEMA 5-15R outlets

  • International Version120V
  • Input Voltage Range100 - 125V
  • Input Frequency40 - 70 Hz
  • Input ConnectionNEMA 5-15P
  • VA Rating1500 VA
  • Watts1200 Watts
  • Double-conversion topology provides zero transfer time to battery
  • Sine wave output protects sensitive equipment from simulated wave issues
  • 1500 VA / 1200 W capacity supports critical enterprise loads
  • Eight NEMA 5-15R outlets connect multiple rack devices
  • Smart Battery Management with 4-hour fast recharge to 90%

1500VA 1200W Online UPS

The CyberPower OL1K5RM is a rackmount uninterruptible power supply with double-conversion topology and sine-wave output. It accepts 100 to 125 V input and provides configurable output at 100, 110, 115, 120 or 125 VAC within two percent. Eight NEMA 5-15R outlets support critical servers, network gear and lab equipment requiring zero transfer time to battery.

Replaces line-interactive units

Double conversion removes the switchover delay found in line-interactive designs, protecting sensitive loads from every fluctuation. The upgrade is worth it when equipment cannot tolerate even a brief break or distorted waveform. Generator compatibility and an input frequency window of 40 to 70 Hz add flexibility for unstable utility or backup generator sources.

4.7 minutes at full load

Three 7 Ah sealed lead-acid batteries deliver 4.7 minutes runtime at 1200 W and 13.5 minutes at half load. Recharge to ninety percent takes four hours. The replaceable RB1270X3B cartridge and optional Extended Battery Modules let you scale runtime for longer outages. USB and serial ports enable monitoring and automated shutdown scripts.

Highlights

  • Double-conversion topology provides zero transfer time to battery
  • Sine wave output protects sensitive equipment from simulated wave issues
  • 1500 VA / 1200 W capacity supports critical enterprise loads
  • Eight NEMA 5-15R outlets connect multiple rack devices
  • Smart Battery Management with 4-hour fast recharge to 90%

Specifications

BrandCyberPower
SeriesEssential Online UPS
ModelOL1K5RM
International Version120V
Input Voltage Range100 - 125V
Input Frequency40 - 70 Hz
Input ConnectionNEMA 5-15P
VA Rating1500 VA
Watts1200 Watts
Output Voltage100/110/115/120/125 VAC +/- 2% (configurable)
Outlets8
Outlet Type8 x NEMA 5-15R
Battery TypeSealed Lead Acid
Battery Run Time4.7 min Full Load / 13.5 min Half Load
Battery Recharge Time4 Hours (0% to 90% charged)
Battery ReplaceableRB1270X3B
AlarmsBattery Mode
Low Battery
Overload
UPS Fault
Interface PortUSB, Serial
ApprovalsUL 1778
CSA C22.2 NO.107.3
FCC Part 15 Class B
RackmountableYes
Surge Energy Rating710 Joules
ProtectionUPS Output Cut Off Immediately or Input Fuse
Circuit Breaker Protection
Overload Protection:
Line Mode: 102% to 130% load for 12s - bypass
Line Mode: 131% to 150% load for 2 s - bypass
>150% load 300ms -no output
Battery Mode: 102% to 130% load for 12 s - shutdown
Battery Mode: >130% for 2 s -shutdown
Bypass Mode: 102% to 110% warning
Bypass Mode: 111% to 130% load for 5min - no output
Bypass Mode: 131% to 150% 16s - no output
>150% for 300ms - no output
TemperatureOperating Temperature: 32 - 104 °F (0 - 40 °C)
Storage Temperature: 5 - 113 °F (-15 - 45 °C)
HumidityOperating Relative Humidity: 0 - 0.9 % (non-condensing)
Storage Relative Humidity: 0 - 0.95% (non-condensing)
Dimensions3.41" x 17.05" x 14.76"
Weight35.71 lbs.
Shipping weight20.00 kg
Package size560 × 480 × 240 mm

Questions about this item

How deep is the rack space needed for this 2U unit?

The OL1K5RM occupies a standard 2U rack height; allow at least 40 cm of usable depth behind the front rails for the chassis, cables and airflow.

Which cable must be connected first when installing the UPS so the batteries activate?

Plug the NEMA 5-15P input cord into a 100-125 V branch circuit, then press the front-panel power button; skipping the mains connection leaves the unit on battery only and it will shut down after 4.7 minutes at full load.

What is the exact replacement battery kit for the three internal 7 Ah cells?

Order the RB1270X3B kit; it contains three matched 12 V 7 Ah sealed lead-acid blocks that restore the original 4.7-minute full-load runtime after a four-hour recharge to 90 percent.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.