We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

CyberPower

CyberPower CP2000PFCRM1U 2000VA 1200W UPS 120V 5x5-20R

SKU CH-MMTT-8E3ZT MPN CP2000PFCRM1U

Rackmount UPS delivering 2000VA and 1200W pure sine-wave power with five NEMA 5-20R outlets and 1050-joule surge protection

  • International Version120V
  • Input Voltage Range91 - 144 VAC
  • Input Frequency57 - 63 Hz
  • Input ConnectionNEMA L5-20P (5-20P Adapter)
  • VA Rating2000 VA
  • Watts1200 W
  • Sine-wave output protects sensitive equipment
  • 2000 VA and 1200 W capacity runs demanding loads
  • 5 NEMA 5-20R outlets supply battery-backed power
  • Rack-mountable 1U design fits standard server cabinets
  • Replaceable sealed lead-acid battery extends service life

2000VA 1200W Sinewave UPS

This CyberPower UPS delivers 2000VA and 1200W of line-interactive backup with a pure sinewave output. It mounts in a 1U rack space and provides five NEMA 5-20R outlets for connected equipment. The unit accepts 120V input through a NEMA L5-20P plug with an included 5-20P adapter and an eight-foot cord. Sealed lead-acid batteries are user-replaceable and recharge in eight hours.

Suited for rack servers needing pure sinewave

IT managers protecting rackmount servers, networking gear or storage arrays that require a clean sinewave waveform will find the 1200W capacity appropriate. The 3.1-minute runtime at full load limits use to short outages or graceful shutdowns. Buyers needing extended runtime for larger loads should consider units with higher wattage or external battery modules. Environments outside the 32 to 104°F operating range are not supported.

1200W real-power rating decides fit

The 1200W rating is the single figure that determines whether your equipment can be supported during an outage. Add the power supplies of every device you intend to connect; if the total exceeds 1200W this UPS cannot carry the load. The five NEMA 5-20R outlets supply both surge protection and battery backup simultaneously.

Highlights

  • Sine-wave output protects sensitive equipment
  • 2000 VA and 1200 W capacity runs demanding loads
  • 5 NEMA 5-20R outlets supply battery-backed power
  • Rack-mountable 1U design fits standard server cabinets
  • Replaceable sealed lead-acid battery extends service life

Specifications

BrandCyberPower
ModelCP2000PFCRM1U
International Version120V
Input Voltage Range91 - 144 VAC
Input Frequency57 - 63 Hz
Input ConnectionNEMA L5-20P (5-20P Adapter)
VA Rating2000 VA
Watts1200 W
Output Voltage120V
Outlets5
Outlet Type5 x NEMA 5-20R
Battery TypeSealed Lead Acid
Battery Run TimeFull Load 3.1 min / Half Load 12.6 min
Battery Recharge Time8 Hours
Battery ReplaceableYes
AlarmsBattery Mode
Low Battery
Overload
Fault
RackmountableYes
Surge Energy Rating1050 Joules
TemperatureOperating Temperature 32 - 104 °F (0 - 40 °C)
Storage Temperature 5 - 113 °F (-15 - 45 °C)
HumidityOperating Relative Humidity: 0 - 95 % (non-condensing)
Storage Relative Humidity: 0 - 95% (non-condensing)
Dimensions1.73" x 17.05" x 21.81"
Weight48.49 lbs.
Shipping weight24.49 kg
Package size680 × 555 × 170 mm

Questions about this item

How often will the sealed lead-acid battery need replacement in the CP2000PFCRM1U?

The sealed lead-acid battery is user-replaceable and typically lasts three to five years; runtime is 3.1 minutes at full load and 12.6 minutes at half load before the low-battery alarm sounds.

What limits continuous output on the CP2000PFCRM1U during extended use?

The 1200 W / 2000 VA rating is the hard limit; overload alarms trigger if connected equipment draws more than 1200 watts continuously.

How loud and hot does the CP2000PFCRM1U get when running all day in a rack?

Operating temperature range is 32 to 104 °F; the line-interactive design runs fans only during battery or AVR events, so idle noise stays low in a 0 to 40 °C rack environment.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.